702 guide: soft tissue has Z 1.63 times ten to the six and reflects 43 per cent at bone; a 52 microsecond echo gives 4.0 cm;">
/en-tutor-prep-alevel-physics-medical-physics-ultrasound-xray-pet/
/en-tutor-prep-alevel-physics-medical-physics-ultrasound-xray-pet/
General Inquiry: info@TutorZone.com.hk
Office Hours: Monday to Saturday - 9:00 AM to 6:00 PM
WhatsApp Monday to Sunday - 24 hours
Hotline: +852 6828 1809
Instant Support: +852 9061 3106

A-Level Physics: 9702 Medical Physics – Ultrasound, X-rays, CT and PET (Tutor Guide)

A-Level Physics: 9702 Medical Physics – Ultrasound, X-rays, CT and PET (Tutor Guide)

  • 2026-11-29

Students treat medical physics as a list of machines to memorise, but the whole topic is three equations: Z equals rho c decides how much reflects, I equals I0 e to the minus mu x decides how much is absorbed, and E equals hf decides the shortest X-ray wavelength and the annihilation photon. Each equation has its own unit trap, and soft tissue, bone, air and a 50 kV tube settle all three.

Objectives — Students can: 1 explain that a piezoelectric crystal changes shape when a p.d. is applied and generates an e.m.f. when its shape changes, so one crystal both sends and receives; 2 use Z equals rho c for soft tissue at 1.63 times ten to the six, bone at 7.75 times ten to the six and air at 396; 3 find a reflection coefficient of 0.43 at a soft tissue to bone boundary and 0.999 at soft tissue to air, and say why gel is needed; 4 use d equals ct over 2 to turn a 52 microsecond echo into 4.0 cm; 5 find 0.025 nm for a 50 kV tube and state that only the accelerating voltage sets it; 6 describe CT as many projections forming one slice, repeated along an axis to build a volume; 7 describe a beta-plus tracer, why annihilation needs two opposite photons for momentum, and find 8.2 times ten to the minus 14 joules per photon.

01 Prerequisites (3-minute check)

If any of these fails, fix it before the lesson starts.

Skill Quick check Pass mark
Wave speed How are speed, frequency and wavelength related c equals f times lambda
Intensity What is intensity and its unit Energy per unit area per second, in watts per square metre
Photon energy Which equation gives the energy of a photon E equals hf, also hc over lambda
The electronvolt How many joules is one electronvolt 1.6 times ten to the minus 19 joules

02 Lesson flow (60 minutes)

Time Stage Tutor does Student does
0-6 minutes Opening check Wave speed, intensity, photon energy, the electronvolt c equals f lambda, watts per square metre, E equals hf, 1.6 times ten to the minus 19
6-24 minutes Scene 1: ultrasound and acoustic impedance The crystal, pulse-echo, Z and reflection, attenuation 1.63 times ten to the six, 43 per cent, 4.0 cm
24-40 minutes Scene 2: X-rays and CT Electron bombardment, minimum wavelength, attenuation and contrast, slices 0.025 nm and a 4.95 ratio between muscle and bone
40-52 minutes Scene 3: PET and annihilation Tracer, beta-plus decay, two opposite photons, time of flight 8.2 times ten to the minus 14 joules and 1.5 cm
52-57 minutes Question types Six routines written out One full question in the routine
57-60 minutes Exit check Three quick questions and the homework Unaided, notes closed

03 Teaching script (read it out)

Scene 1: Ultrasound — one crystal, one echo, three equations

Start with the transducer. A piezoelectric crystal works both ways: apply a p.d. and it changes shape, so it can vibrate and launch ultrasound; let a sound wave squeeze it and it generates an e.m.f., so it can receive. One probe does both, which is why scanning is a pulse-echo method: send a short pulse, then listen.
Next, reflection. When sound crosses from one tissue to another, some energy reflects if the specific acoustic impedances differ. Impedance is Z equals rho c, density times speed, in kilograms per square metre per second. Soft tissue with 1060 and 1540 gives 1.63 times ten to the six; bone with 1900 and 4080 gives 7.75 times ten to the six; air with 1.2 and 330 gives 396. Put the three side by side and students see bone is the same order as soft tissue while air is four orders smaller.
The intensity reflection coefficient is the difference over the sum, squared. Soft tissue to bone: 7.75 minus 1.63 is 6.12, 7.75 plus 1.63 is 9.38, and the square of the ratio is 0.43, so 43 per cent is reflected. Soft tissue to air: 1.63 times ten to the six against 396 is four orders apart, so the coefficient is almost 1 and 99.9 per cent reflects. That is why gel is spread between probe and skin, to replace the air layer; without it the pulse bounces off the skin and nothing inside is seen. Make the class say that, not memorise it.
Third, depth and attenuation. The pulse travels there and back, so d equals c times t over 2, and forgetting the 2 doubles every depth, the most common error. For a 52 microsecond echo: 1540 times 52 times ten to the minus 6 is 0.080 m, halved to 0.040 m, so 4.0 cm. Attenuation is I equals I0 e to the minus mu x, where mu is per centimetre so x must be in centimetres. With mu 0.40 per cm, 5 cm leaves e to the minus 2, 13.5 per cent; 10 cm leaves 1.8 per cent. The half-value thickness is ln2 over mu, 1.73 cm, so intensity halves every 1.73 cm.
Finish with resolution: shorter wavelength resolves finer detail. At 1 MHz in soft tissue the wavelength is 1540 over 10 to the 6, 1.54 mm; at 5 MHz it is 0.31 mm. Higher frequency sees finer but attenuates faster, which is why the abdomen uses low frequency and the eye or thyroid uses high frequency.
Student task: fat has Z 1.38 times ten to the six and muscle 1.70 times ten to the six. Find the reflection coefficient and say what it means for the image.

A line you can read aloud: “Z equals rho c, and the bigger the mismatch the more reflects; the echo travels both ways, so depth is c t over 2; attenuation is I0 e to the minus mu x with mu and x in the same unit.”

Scene 2: X-rays and CT — the voltage sets the shortest wavelength, attenuation sets the contrast

Scene two is X-rays. A tube accelerates electrons through a high p.d.; when they hit the metal target and decelerate sharply their kinetic energy becomes photons, which is bremsstrahlung. An electron accelerated through V volts has kinetic energy eV; if all of it becomes one photon, that photon has the maximum energy and the minimum wavelength, so eV equals hc over lambda min and lambda min equals hc over eV.
At 50 kV: 6.63 times ten to the minus 34 times 3.00 times ten to the eight gives 1.99 times ten to the minus 25 on top; 1.60 times ten to the minus 19 times 5.0 times ten to the 4 gives 8.0 times ten to the minus 15 below; the quotient is 2.5 times ten to the minus 11 m, 0.025 nm. Students should hold on to the inverse relation: double the voltage and halve the minimum wavelength, so 100 kV gives 0.012 nm. Also say plainly that the minimum wavelength depends only on the accelerating voltage, not on whether the target is tungsten or copper; the target only sets the positions of the characteristic lines. This is the most commonly confused point.
Next, attenuation and contrast. X-rays obey the same I equals I0 e to the minus mu x, but mu differs strongly between tissues: bone contains calcium and absorbs well, muscle is mostly water and absorbs poorly. With muscle 0.20 per cm and bone 0.60 per cm, after 4 cm muscle leaves e to the minus 0.8, 45 per cent, and bone leaves e to the minus 2.4, 9 per cent, a ratio of 4.95, and that ratio is the contrast. Make students say contrast is a ratio of intensities reaching the detector, not the colour white; regions that are too thick or too thin lose contrast, so voltage and exposure are adjusted.
Third, CT. A plain radiograph collapses a three-dimensional patient into two dimensions, so structures overlap. CT instead rotates the tube and detectors around the patient, takes many projections of one section from different angles and computes one two-dimensional slice, then moves along the axis and repeats, finally stacking the slices into a volume. Students should say the two steps in one breath: many angles make one slice, the axis is then repeated to build the volume.
Student task: put 80 kV into the minimum-wavelength equation, find the wavelength, and say whether it is longer or shorter than at 50 kV and by what factor.

A line you can read aloud: “The shortest wavelength is hc over eV and only the voltage sets it, so double the voltage and halve it; contrast comes from the attenuation ratio, not from colour; CT makes one slice from many angles, then stacks slices along the axis.”

Scene 3: PET — one positron, two opposite photons, one time difference

Scene three is PET. Begin with the tracer: a substance containing radioactive nuclei is put into the body and taken up by the tissue being studied, for example a glucose analogue that a tumour takes up heavily, so the radioactivity maps the metabolic activity. The PET nuclide decays by beta-plus, emitting a positron.
A positron is the antiparticle of the electron, same mass and opposite charge. It travels only a millimetre or two in tissue before meeting an electron, and the pair annihilates. Annihilation is not disappearance: the mass becomes energy, and the rest energy of the two electrons, each mc squared, is shared by two photons. Why two? Because the momentum before is almost zero and a photon carries momentum, so two photons must leave in opposite directions with equal and opposite momenta. That is momentum conservation, not a fact to memorise.
Numbers: the rest energy of one electron is 9.11 times ten to the minus 31 times 9.00 times ten to the sixteen, 8.2 times ten to the minus 14 joules; divided by 1.6 times ten to the minus 19 it is 5.1 times ten to the 5 electronvolts, about 511 keV. Each of the two photons carries that energy and they leave back to back, so the total is 1.6 times ten to the minus 13 joules, exactly the rest energy of the pair. Have students multiply 2 by 8.2 and 2 by 511 and check that both sides agree.
Detection: a ring of detectors outside the body catches two photons at once, one annihilation event. The arrival-time difference tells you where on the line between the two detectors the event happened: a difference of 1.0 times ten to the minus 10 s means a path difference of 3.0 cm, so the event is 1.5 cm from the midpoint. Stack many events and you get the three-dimensional tracer concentration. Ask students to contrast this with X-ray and CT, which image absorption, while PET images uptake, so PET shows function rather than structure.
Student task: if timing resolution is only 5.0 times ten to the minus 10 s, what is the positional uncertainty along the line, and why does better timing sharpen the image?

A line you can read aloud: “Annihilation gives two photons back to back because momentum is conserved; each carries 511 keV, 8.2 times ten to the minus 14 joules; the time difference times c over 2 gives the position along the line.”

04 Question types and worked steps

Type Example Steps Answer
Acoustic impedance Soft tissue, density 1060, speed 1540 1 Z equals rho c; 2 unit is kilograms per square metre per second; 3 keep both terms in SI 1.63 times ten to the six
Reflection coefficient Soft tissue against bone 1 find both Z values; 2 difference over sum; 3 square it for intensity 0.43, so 43 per cent reflected
Pulse-echo depth Echo after 52 microseconds 1 d equals ct over 2; 2 convert time to seconds; 3 missing the 2 doubles the depth 4.0 cm
Attenuation and half-value thickness mu 0.40 per cm, x 5 cm 1 I equals I0 e to the minus mu x; 2 mu and x in the same unit; 3 half-value is ln2 over mu 13.5 per cent left, 1.73 cm half-value
X-ray minimum wavelength 50 kV 1 lambda min equals hc over eV; 2 the electron energy eV in joules; 3 the target does not matter 0.025 nm
PET photons and position Electron rest energy, time difference 1.0 times ten to the minus 10 s 1 E equals mc squared; 2 each photon takes half; 3 position is c delta t over 2 8.2 times ten to the minus 14 joules and 1.5 cm
Sanity check (teach this): Four checks. First, a reflection coefficient must lie between 0 and 1: a value above 1 means the difference and sum are swapped, a negative means the square was forgotten. Second, Z is in kilograms per square metre per second, so density must be in kilograms per cubic metre and speed in metres per second; using grams per cubic centimetre makes Z a thousand times too small. Third, mu and x in the attenuation equation must share a length unit: mu in per cm means x in cm, and mixing metres with per cm makes the answer a hundred times too small. Fourth, the X-ray minimum wavelength is inversely proportional to the accelerating voltage and independent of the target; an answer that changes with the target is a characteristic line, not the minimum.

05 Independent practice (3 questions)

Question Answer What to watch
Bone has density 1900 and speed 4080, and soft tissue has Z 1.63 times ten to the six. Find the Z of bone and the reflection coefficient between them. 7.75 times ten to the six and 0.43 Multiply for Z, then difference over sum and square
An ultrasound pulse returns after 52 microseconds in soft tissue at 1540 m/s. Find the depth of the reflector. 4.0 cm There and back, so halve c times t
An X-ray tube runs at 50 kV. Find the minimum wavelength, taking h as 6.63 times ten to the minus 34. 0.025 nm lambda min equals hc over eV, with the electron energy in joules

06 Common mistakes and what to say

Mistake Student writes Say this
Forgetting the factor of 2 in depth 52 microseconds gives 8.0 cm “The pulse travels there and back, so c t is the total path; the depth is always half of it, otherwise every answer is double.”
Squaring missed in the reflection coefficient 0.65 instead of 0.43 for soft tissue to bone “Amplitude ratio is the first power and intensity ratio is the square; when the question says intensity reflection coefficient, square it.”
Mixing units in Z Putting density in at 1.06 grams per cubic centimetre “Z equals rho c needs kilograms per cubic metre; grams per cubic centimetre makes it a thousand times too small and every comparison after that is wrong.”
Thinking the target sets the minimum wavelength Answering that a tungsten target gives 0.025 nm “Only the accelerating voltage sets the shortest wavelength; the target only moves the characteristic lines, so changing the target at fixed voltage changes nothing.”

07 Homework (paper, section and question numbers)

08 Exit check (last 5 minutes)

Question Answer Decision
Roughly what is the reflection coefficient between soft tissue and air Almost 1, about 99.9 per cent Answering 0.43 means bone and air were swapped
How does the minimum wavelength change from 50 kV to 100 kV It halves, 0.025 nm to 0.012 nm Doubling it treats an inverse relation as direct
Why must annihilation give two photons Momentum conservation: they leave in opposite directions One photon would leave momentum unaccounted for

09 Tutor FAQ

Why is gel needed on an ultrasound probe?

With air between probe and skin the acoustic impedance of soft tissue and air differ by four orders of magnitude, so the reflection coefficient is almost 1 and the pulse bounces off the surface. Gel has an impedance close to soft tissue, replaces the air layer and lets the sound in.

How is CT different from a plain X-ray?

A plain radiograph is one projection, so structures in front of and behind each other overlap into a single flat image. CT rotates the tube and detectors, takes many projections of one section, computes a two-dimensional slice, repeats along the axis and stacks the slices into a volume, so overlapping structures separate.

Why does PET use a beta-plus nuclide rather than alpha or beta-minus?

PET localises events from the two back-to-back photons of annihilation. Beta-plus decay emits a positron, which annihilates with an electron in the tissue and gives two 511 keV photons in opposite directions, so two detectors catching them define a line. Alpha particles stop in millimetres and beta-minus gives no positron, so neither can do this.

Find a tutor — freeTutor Registration →

A TutorZone lesson-prep guide. Written by the TutorZone team; questions and lesson flow are original and are not taken from any school or publisher material.

Join as a tutor or coach — academic, music, sports, arts, STEM. Free to register. See how it works →