S6 Design and Applied Technology Practice Paper | beam reactions, Euler buckling, water pressure, pump power, transformer loss and solar payback
- 2026-11-17
S6 Design and Applied Technology practice paper with answers: beam reactions, bending stress, buckling load, pump power, transformer loss and solar payback. Free PDF.
Question 1 Reactions and bending stress of a beam
A simply supported beam spans 8.0 m and carries a point load of 12 kN at 3.0 m from the left support. Its rectangular section is 150 mm wide and 300 mm deep, and the allowable bending stress is 12.0 MPa.
| # | Question | Answer and marking notes |
|---|---|---|
| 1 | (a) Taking moments about the supports, calculate the reaction at each end. | Answer: right reaction = 4.5 kN and left reaction = 7.5 kN. |
| 2 | (b) Find the maximum bending moment and state where it occurs. | Answer: M = 22.5 kN m, directly under the point load. |
| 3 | (c) Calculate the section modulus and the maximum bending stress. | Answer: Z = 2,250,000 mm cubed and the stress is 10.0 MPa. |
| 4 | (d) Find the stress utilisation and judge whether the beam is safe under the allowable stress. | Answer: utilisation 83.3 per cent, so the beam is safe but with little reserve. |
Question 2 Euler buckling load of a steel column
A steel column is pinned at both ends, 3.0 m long, with E = 200 GPa, second moment of area 8.0 x 10^-7 m^4 and effective length factor 1.0. The applied load is 60 kN.
| # | Question | Answer and marking notes |
|---|---|---|
| 5 | (a) Use Euler formula to calculate the critical buckling load in newtons to three significant figures. | Answer: the critical load is about 175 kN. |
| 6 | (b) Find the ratio of the critical load to the applied load and comment on its adequacy. | Answer: the ratio is 2.92, well above the usual requirement of 2.0. |
| 7 | (c) If the column length is doubled to 6.0 m, find the new critical load and explain the change. | Answer: 44 kN, one quarter of the original, because the critical load varies with the inverse square of length. |
| 8 | (d) Suggest two practical ways to raise the critical load of the column and explain why they work. | Answer: fix the ends to shorten the effective length, and brace the weak axis or use a section with a larger second moment of area. |
Question 3 Hydrostatic pressure and stored water weight
In a housing estate the water surface in the tank is 25.0 m above the lowest tap. The tank is a cylinder 4.0 m in diameter with 6.0 m of water. Take water density as 1,000 kg per cubic metre and g as 9.8 m per second squared.
| # | Question | Answer and marking notes |
|---|---|---|
| 9 | (a) Find the hydrostatic pressure at the lowest tap in kilopascals. | Answer: 245.2 kPa. |
| 10 | (b) Calculate the stored volume and the weight of the water in kilonewtons. | Answer: volume 75.4 cubic metres and weight 740 kN. |
| 11 | (c) Find the pressure at 12.0 m below the water surface. | Answer: 117.7 kPa, which depends only on depth. |
| 12 | (d) If the tap needs at least 150 kPa to supply water, find the minimum height of the water surface. | Answer: at least 15.29 m above the tap. |
Question 4 Pump power and electricity cost
A pumping station lifts water through 18.0 m at a flow of 0.02 cubic metres per second. The pump efficiency is 0.70, electricity costs 1.20 dollars per kWh and the pump runs 6.0 hours a day.
| # | Question | Answer and marking notes |
|---|---|---|
| 13 | (a) Calculate the hydraulic power of the pump in kilowatts. | Answer: 3.53 kW. |
| 14 | (b) Find the electrical input power required. | Answer: 5.05 kW. |
| 15 | (c) Find the daily energy use and the daily electricity cost. | Answer: 30.27 kWh a day costing 36.33 dollars. |
| 16 | (d) If a new impeller raises efficiency to 0.80, find the new input power and the percentage saved. | Answer: 4.41 kW, a saving of 12.5 per cent. |
Question 5 Step up transformer and line loss
A step up transformer raises the voltage from 11 kV to 132 kV with a primary current of 400 amperes. The total resistance of the transmission line is 6.0 ohms and the transformer is ideal.
| # | Question | Answer and marking notes |
|---|---|---|
| 17 | (a) Find the transmitted power and the secondary current. | Answer: 4.40 MW and 33.3 amperes. |
| 18 | (b) Find the turns ratio of the transformer. | Answer: a step up ratio of 1 to 12. |
| 19 | (c) At 132 kV, find the line power loss and its percentage of the transmitted power. | Answer: about 6.67 kW, or 0.15 per cent. |
| 20 | (d) If the same power were sent at 11 kV, find the loss, its percentage and the ratio between the two cases. | Answer: 960 kW or 21.8 per cent, 144 times the loss at high voltage. |
Question 6 Payback period of a rooftop solar system
A school roof carries 30 solar panels of 400 W peak each. The site has 4.0 peak sun hours a day with a performance ratio of 0.80. The system costs 180,000 dollars, electricity is 1.20 dollars per kWh and each kWh avoids 0.70 kg of carbon dioxide.
| # | Question | Answer and marking notes |
|---|---|---|
| 21 | (a) Calculate the daily energy yield in kilowatt hours. | Answer: 38.4 kWh a day. |
| 22 | (b) Find the annual energy yield and the annual saving. | Answer: 14,016 kWh a year, saving 16,819 dollars. |
| 23 | (c) Find the simple payback period in years to two decimal places. | Answer: 10.70 years. |
| 24 | (d) Find the annual carbon dioxide avoided in tonnes and comment on whether the payback makes the investment worthwhile. | Answer: 9.8 tonnes a year; with a module life of 20 to 25 years a 11 year payback leaves over a decade of net saving. |
Find a tutor — freeTutor Registration →
A TutorZone practice paper; original questions and passages, not publisher material.