/en-tutor-prep-s2-geography-hk-rivers-flooding/
/en-tutor-prep-s2-geography-hk-rivers-flooding/
General Inquiry: info@TutorZone.com.hk
Office Hours: Monday to Saturday - 9:00 AM to 6:00 PM
WhatsApp Monday to Sunday - 24 hours
Hotline: +852 6828 1809
Instant Support: +852 9061 3106

Junior Secondary Geography — Hong Kong Rivers and Flooding Prep Guide for Tutors — Runoff Coefficients, 60 Cubic Metres per Second and 25 Minutes of Detention

Junior Secondary Geography — Hong Kong Rivers and Flooding Prep Guide for Tutors — Runoff Coefficients, 60 Cubic Metres per Second and 25 Minutes of Detention

  • 2026-11-21

The same storm falling on a building site and on woodland can raise the river twice as high. This lesson explains flooding with four numbers: catchment rainfall, runoff coefficient, peak discharge and detention time.

Objectives — Students will be able to: (1) use a 30 square kilometre catchment and 2,200 millimetres of annual rainfall to get 66 million cubic metres, and show that a runoff coefficient rising from 0.35 to 0.70 lifts runoff from 23.1 to 46.2 million cubic metres; (2) use a 20 metre width, 1.5 metre depth and 2 metres per second to get a peak of 60 cubic metres per second against a channel capacity of 40, an excess of 50 per cent; (3) show that 30,000 cubic metres of storage absorbs 1,500 seconds or 25 minutes, and that a 1-in-50-year flood has a 2 per cent annual chance and a 39.7 per cent chance within 25 years.

01 Prerequisites (3-minute check)

If any of these fails, fix it before the lesson starts.

Skill Quick check Pass mark
Volume and units How many square metres are in 30 square kilometres 30 million square metres
Percentages What is 0.35 as a percentage 35 per cent
Discharge Which three quantities multiply to give discharge Width, depth and velocity

02 Lesson flow (60 minutes)

Time Stage Tutor does Student does
0-8 min Opening diagnosis Ask why the same storm floods the city but not the countryside Write two reasons and compare with a partner
8-22 min Act one: catchment and runoff Calculate 66 million cubic metres, then compare 0.35 and 0.70 Recalculate and write both runoff figures
22-38 min Act two: peak discharge and capacity Multiply width, depth and velocity to get 60, compare with 40 Work out the excess and express it as a percentage
38-50 min Act three: detention, return period and warning Show 25 minutes of storage, then 2 per cent and 39.7 per cent Write two flood measures for a village, each with a number
50-56 min Independent practice Hand out three items and patrol, prompt only Work alone and circle the unit conversion step
56-60 min Exit check Read three questions, record how many were wrong Answer orally and note one concept still unclear

03 Teaching script (read it out)

Scene 1: Act one: the same rain can produce twice the runoff

Start with the rainfall volume: 30 square kilometres is 30 million square metres, and 2,200 millimetres is 2.2 metres, so the product is 66 million cubic metres. That catchment receives 66 million cubic metres of rain a year, roughly the volume of 26 standard 50-metre pools.

Not all of it reaches the river. Woodland has a runoff coefficient near 0.35, so 66 million times 0.35 gives 23.1 million cubic metres. Concrete raises the coefficient to 0.70, giving 46.2 million cubic metres. The river has twice as much water to carry from the same storm.

So urbanisation making floods worse is not a slogan, it is the arithmetic of 0.35 becoming 0.70. Students who have multiplied both numbers understand why planting and permeable paving help: they pull the coefficient back towards 0.35.

66 million times 0.35 and 0.70: runoff rises from 23.1 to 46.2 million cubic metres

Scene 2: Act two: peak discharge is three quantities, capacity is the fourth

Discharge is width times depth times velocity: 20 metres times 1.5 metres times 2 metres per second gives 60 cubic metres per second. Compare that with channel capacity of 40, and the peak exceeds capacity by 20 cubic metres per second, or 50 per cent.

Students often confuse depth with discharge. Doubling depth doubles discharge; doubling velocity also doubles discharge. What decides flooding is all three rising together, which is exactly what urbanisation does: straightened channels raise velocity, fast drainage raises depth, and building beside the river narrows the width.

Handle the return period carefully: a 1-in-50-year flood has a 2 per cent chance every year, not one flood every 50 years. The chance of meeting at least one in 25 years is one minus 0.98 to the power of 25, which is 39.7 per cent.

Peak of 60 against capacity 40: an excess of 20, or 50 per cent

Scene 3: Act three: storage buys 25 minutes, warning buys 1.5 hours

Detention storage holds water and releases it later. 30,000 cubic metres divided by the excess of 20 cubic metres per second gives 1,500 seconds, or 25 minutes. That is enough for downstream residents to be warned, close shutters and move cars out of a basement car park.

The other time gap is the lag between peak rainfall and peak flow. A rural catchment lags about 2.5 hours; straightened channels and impermeable surfaces cut that to 1 hour, losing 1.5 hours. Those lost 1.5 hours are exactly the response time the warning system and residents had.

Every measure must carry a number: doubling storage to 60,000 cubic metres buys 50 minutes, and a warning line set at the 2 per cent annual chance is defensible. A measure without a number is not a measure.

30,000 divided by 20 is 1,500 seconds, or 25 minutes; the lag falls from 2.5 hours to 1 hour

04 Question types and worked steps

Type Example Steps Answer
Rainfall volume 30 square kilometre catchment, 2,200 millimetres a year Convert area and depth, then multiply 66 million cubic metres
Runoff comparison Coefficients of 0.35 and 0.70 Multiply both, then compare 23.1 and 46.2 million cubic metres, double
Peak discharge Width 20 m, depth 1.5 m, velocity 2 m per second Multiply all three, compare with capacity 60 cubic metres per second, 50 per cent above capacity
Detention time 30,000 cubic metres, excess of 20 cubic metres per second Divide volume by discharge 1,500 seconds, or 25 minutes
Sanity check (teach this): Sanity checks: convert square kilometres to square metres by multiplying by one million and millimetres to metres by dividing by a thousand before multiplying; a runoff coefficient must lie between 0 and 1 and runoff can never exceed rainfall; discharge is cubic metres per second, never cubic metres; capacity and peak must share one unit; a return period is an annual probability, not a fixed cycle; detention time in seconds becomes minutes only after dividing by 60.

05 Independent practice (3 questions)

Question Answer What to watch
30 square kilometres with 2,200 millimetres of rain: what volume? 66 million cubic metres (30 million times 2.2) Check that units are converted before multiplying
A peak of 60 against capacity 40: what is the excess and the percentage? 20 cubic metres per second, 50 per cent Check that capacity is the denominator
30,000 cubic metres of storage against an excess of 20 per second: how long? 1,500 seconds, or 25 minutes Check the division by 60

06 Common mistakes and what to say

Mistake Student writes Say this
Multiplying before converting units 30 times 2,200 gives 66,000 Square kilometres become square metres times a million, millimetres become metres divided by a thousand, and the answer is 66 million cubic metres.
Treating the coefficient as a subtraction 0.70 minus 0.35 means 0.35 times more Compare the two products: 23.1 million against 46.2 million, which is double.
Confusing depth with discharge Depth is 1.5 metres so discharge is 1.5 Discharge is width times depth times velocity: 20 times 1.5 times 2, giving 60 cubic metres per second.
Reading a return period as a cycle One in 50 years, so it must happen within 50 years It is 2 per cent each year; within 25 years the chance is 39.7 per cent, not a certainty.

07 Homework (paper, section and question numbers)

08 Exit check (last 5 minutes)

Question Answer Decision
Volume for 30 square kilometres and 2,200 millimetres 66 million cubic metres If wrong, reteach unit conversion in act one
Excess percentage when peak is 60 and capacity is 40, and the formula 50 per cent; width times depth times velocity If wrong, reteach the discharge formula in act two
How long 30,000 cubic metres lasts against an excess of 20 per second 1,500 seconds, or 25 minutes If wrong, reteach the division in act three

09 Tutor FAQ

Which year group is this for

S2 fits best. From S3 the topic adds catchment management and engineering costs, but the three calculations stay the same.

What if we have no local gauge data

The four numbers on this page are enough: catchment area, annual rainfall, channel dimensions and storage volume are standard textbook assumptions, and the reasoning matters more than the gauge.

Is there practice material

Yes. Two homework links go to Section 07 practice, where students check the unit conversion and the discharge formula.

Find a tutor — freeTutor Registration →

A TutorZone lesson-prep guide. Written by the TutorZone team; questions and lesson flow are original and are not taken from any school or publisher material.

Join as a tutor or coach — academic, music, sports, arts, STEM. Free to register. See how it works →