Paper 2: current, fuses and household circuits
Chapter practice with ten items, answers and a one-line note for each, about 25 minutes.
| Item | Detail |
|---|---|
| Questions | 10 |
| Suggested time | 25 |
| Difficulty mix | Foundation 4 · Intermediate 2 · Challenge 2 · Error redo 2 |
| Chapter | Chapter: Electrical power and household electrical safety |
| Level | Advanced |
| # | Answer | One-line note |
|---|---|---|
| 1 | 10 A | I = P / V = 2200 / 220 = 10 A. |
| 2 | 13 A | The rating must be just above the normal current of 10 A; a 3 A fuse would blow at once. |
| 3 | 1.2 kWh | Total power is 200 W, so 200 x 6 = 1200 Wh = 1.2 kWh. |
| 4 | 180 W | P = I2R = 9 x 20 = 180 W. |
| 5 | $108 | 1.5 x 2 x 30 = 90 kWh, and 90 x 1.2 = $108. |
| 6 | Each appliance can be switched on or off independently | In parallel every appliance gets the full 220 V, so switching one off does not stop the others. |
| 7 | It carries the leakage current to the ground so nobody is shocked | If the casing becomes live, current flows down the earth wire instead of through a person. |
| 8 | 4 A | 880 / 220 = 4 A. |
| 9 | 10 hours | 1000 Wh / 100 W = 10 h; kWh divided by kW gives hours. |
| 10 | Total current is 15 A, above 13 A, so the fuse blows | 2200 + 1100 = 3300 W, and 3300 / 220 = 15 A, so the fuse melts. |
Mark your answers on the spot and redo the missed items two days later; always convert watts to kilowatts and minutes to hours first.Tutor Registration →