Paper 2: current, fuses and household circuits

Paper 2: current, fuses and household circuits

  • 2026-11-21

Paper 2: current, fuses and household circuits

Chapter practice with ten items, answers and a one-line note for each, about 25 minutes.

Paper 2 Ten items on this chapter with answers for immediate marking.

01 Paper details (check answers afterwards)

Item Detail
Questions 10
Suggested time 25
Difficulty mix Foundation 4 · Intermediate 2 · Challenge 2 · Error redo 2
Chapter Chapter: Electrical power and household electrical safety
Level Advanced

02 Questions (10 items)

  1. FoundationA 220 V kettle is rated at 2200 W. What current does it draw?
  2. FoundationWhich fuse suits that kettle: 3 A or 13 A?
  3. FoundationTwo 100 W lamps run together for 6 hours. What is the total energy used?
  4. FoundationA current of 3 A passes through a 20 ohm resistor. What power is dissipated?
  5. IntermediateA 1500 W heater runs 2 hours a day for 30 days. What is the bill at $1.2 per kWh?
  6. IntermediateWhy are household sockets wired in parallel rather than in series?
  7. ChallengeWhat does the earth wire do when there is a leakage?
  8. ChallengeA 220 V rice cooker is rated at 880 W. What current does it take?
  9. Error redoFor how many hours can 1 kWh light a 100 W lamp?
  10. Error redoA 220 V circuit has a 13 A fuse. What happens if 2200 W and 1100 W appliances run together?

03 Answers and one-line notes

# Answer One-line note
1 10 A I = P / V = 2200 / 220 = 10 A.
2 13 A The rating must be just above the normal current of 10 A; a 3 A fuse would blow at once.
3 1.2 kWh Total power is 200 W, so 200 x 6 = 1200 Wh = 1.2 kWh.
4 180 W P = I2R = 9 x 20 = 180 W.
5 $108 1.5 x 2 x 30 = 90 kWh, and 90 x 1.2 = $108.
6 Each appliance can be switched on or off independently In parallel every appliance gets the full 220 V, so switching one off does not stop the others.
7 It carries the leakage current to the ground so nobody is shocked If the casing becomes live, current flows down the earth wire instead of through a person.
8 4 A 880 / 220 = 4 A.
9 10 hours 1000 Wh / 100 W = 10 h; kWh divided by kW gives hours.
10 Total current is 15 A, above 13 A, so the fuse blows 2200 + 1100 = 3300 W, and 3300 / 220 = 15 A, so the fuse melts.

04 What to do after marking

  • After marking, redo only the wrong items and write down which step went wrong (formula, unit, or misread number).
  • Repeat the same item two days later; move to the next paper only when both attempts are correct.
  • Parents only need the answer and note columns; there is no need to explain every item.

Mark your answers on the spot and redo the missed items two days later; always convert watts to kilowatts and minutes to hours first.Tutor Registration →

Questions and answers are written originally by the TutorZone team and are not taken from any school, publisher or examination authority paper. Every value is checked by computer.

Join as a tutor or coach — academic, music, sports, arts, STEM. Free to register. See how it works →