Every student uses the cloud, yet few can say which layer they are responsible for. This lesson uses one responsibility line and two calculations to turn a slogan into an answerable question.
01 Prerequisites (3-minute check)
If any of these fails, fix it before the lesson starts.
| Skill | Quick check | Pass mark |
|---|---|---|
| Percentages | Eight servers draw 2,000 W and save 800 W, so what share is saved | 40 per cent |
| Unit conversion | 800 W for 24 hours is how many kWh | 19.2 kWh |
| Multiplication | 19.2 kWh a day over 365 days | 7,008 kWh |
| Decimals | What is 99.9 per cent as a decimal | 0.999, leaving 0.001 as downtime |
02 Lesson flow (45 minutes)
| Time | Stage | Tutor does | Student does |
|---|---|---|---|
| 0-6 min | Entry check | Ask 40 per cent, 19.2 kWh, the annual figure and 0.001; keep answers on the board | Spoken answers, working on paper |
| 6-16 min | Act one: three service layers, one responsibility line | IaaS runs your own OS, PaaS runs only your code, SaaS you only use; draw the line bottom to top | Students give a SaaS example they use |
| 16-26 min | Act two: virtualisation is slicing a cake | A hypervisor slices one 16-core 64 GB machine into four virtual machines, each with its own OS | Students contrast a VM with a physical machine |
| 26-36 min | Act three: consolidation power and availability | Eight 250 W become two 600 W, saving 800 W; 19.2 kWh a day and 8,409.6 a year; 99.9 per cent gives 8.76 hours | Students compute the saving and downtime |
| 36-42 min | Question types: layers, slicing, power, availability | The same numbers asked four ways | Students do one and write the unit |
| 42-45 min | Exit check | Three spoken questions; note which act each error comes from | All three correct |
03 Teaching script (read it out)
Scene 1: Act one: three layers, differing in how far your responsibility reaches
A company rents a virtual server and installs its own database: is that IaaS or PaaS, and why?
Scene 2: Act two: virtualisation slices one machine for several users
What is the biggest risk of four virtual machines on one physical host, and how do you fix it?
Scene 3: Act three: consolidation is subtraction, availability is multiplication
How many hours of downtime separate 99.9 from 99.99 per cent, and why is the price so different?
04 Question types and worked steps
| Type | Example | Steps | Answer |
|---|---|---|---|
| Classify the layer | Renting a virtual server and installing the OS and database yourself | Ask how far the user responsibility reaches | IaaS, everything above the OS is yours |
| Virtualisation concept | One 16-core 64 GB machine split into four virtual machines | The hypervisor slices, each VM has its own OS | Four VMs share one physical host |
| Consolidation saving | Eight 250 W servers become two at 600 W | Subtract the totals, divide by the original total | 800 W saved, that is 40 per cent |
| Availability | Downtime in a year at 99.9 per cent | 8,760 hours times 0.001 | 8.76 hours |
05 Independent practice (3 questions)
| Question | Answer | What to watch |
|---|---|---|
| Eight servers draw 2,000 W and consolidation gives 1,200 W: what share is saved | 40 per cent, that is 800 W | Check the denominator is the original 2,000 W |
| 0.8 kW saved runs for a day: how many kWh | 19.2 kWh | 0.8 times 24, after converting watts to kilowatts |
| 99.9 per cent availability: downtime a year | 8.76 hours | 8,760 times 0.001 |
06 Common mistakes and what to say
| Mistake | Student writes | Say this |
|---|---|---|
| Confusing IaaS with PaaS | Calling a rented virtual server with a self-installed database PaaS | One line settles it: do you install and update the operating system? If yes, it is IaaS. |
| Treating a VM as a physical machine | Saying one host can hold only one virtual machine | Virtualisation exists to put several VMs on one host, otherwise there is no consolidation at all. |
| Slipping on kWh | Multiplying 800 by 24 to get 19,200 kWh | 800 is watts, so divide by 1,000 first to get 0.8 kW, then multiply by 24 for 19.2 kWh, a thousandfold difference. |
| Reading higher availability as more downtime | Answering 87.6 hours for 99.99 per cent | The higher the percentage, the smaller the leftover share, so 99.99 per cent leaves 0.876 hours. Count the decimal places. |
07 Homework (paper, section and question numbers)
- S4 ICT Practice Paper 1, cloud computing and virtualisation section — Section A, questions 1 to 4
08 Exit check (last 5 minutes)
| Question | Answer | Decision |
|---|---|---|
| A rented virtual server with your own OS: which service layer | IaaS | Wrong: reteach act one, who runs the operating system |
| Eight 250 W servers become two at 600 W: the saving | 800 W, that is 40 per cent | Wrong: reteach act three, divide by the original total |
| Downtime a year at 99.9 per cent availability | 8.76 hours | Wrong: reteach act three, 8,760 times 0.001 |
09 Tutor FAQ
Which year level is this for?
Hong Kong S4 ICT uses cloud computing and virtualisation to test service layer judgement and resource arithmetic. The S3 work on percentages and unit conversion is the prerequisite, so revise the difference between kW and kWh first.
Is 45 minutes enough?
Yes, provided act one gets ten minutes. The layers are settled by one responsibility line, so never read the acronyms out one by one or students only memorise letters.
Are these a real company figures?
No. 250 W, 600 W and 1.2 dollars a unit are teaching numbers. Real data centres differ widely in power density and tariffs, and the method and direction of the judgement are the point.