Marks are lost in analytical questions from units and ratios rather than from unfamiliar formulae. In A = epsilon c l the concentration must be in mol per dm3 and the path length in cm, and mixing either costs orders of magnitude. For chromatography, an Rf only means something at the same solvent, same stationary phase and same temperature.
01 Prerequisites (3-minute check)
If any of these fails, fix it before the lesson starts.
| Skill | Quick check | Pass mark |
|---|---|---|
| Concentration units | Relation between mol per dm3 and mol per cm3 | 1 mol per dm3 is 1000 times 1 mol per cm3 |
| Proportional reasoning | A 0.240 corresponds to 0.100, so what does A 0.360 give | 0.150 |
| Significant figures | How many figures 0.150 should carry | Three, matching the 0.100 given |
| Chromatography principle | Why dyes separate | Different adsorption to the stationary phase and solubility in the mobile phase |
02 Lesson flow (60 minutes)
| Time | Stage | Tutor does | Student does |
|---|---|---|---|
| 0-8 min | Entry questions | What links absorbance and concentration, how do transmittance and absorbance convert, can Rf exceed 1 | Oral answers; the tutor writes A = epsilon c l with the three units labelled |
| 8-24 min | Act 1: unit discipline in A = epsilon c l | With A 0.480, epsilon 2400 and l 1.0 cm, c is A over epsilon l, giving 2.00 x 10 to the minus 4 mol per dm3; the cm cancels against cm to the minus 1 in epsilon | Students substitute and write the unit, correcting any wrong unit on the spot |
| 24-36 min | Act 2: calibration curve and interpolation | Four standards give a straight line of A against c; an unknown with A 0.360 falls between 0.240 and 0.480 and interpolates to 0.150; if the sample was diluted fivefold the original is 0.750 | Students interpolate on the graph and state the dilution direction |
| 36-46 min | Act 3: transmittance and the useful range | A 0.480 gives T equal to 10 to the minus 0.480, which is 0.331 or 33.1%; readings are most reliable between about 0.2 and 0.8, so concentrated samples are diluted | Students compute T and explain why dilution is needed |
| 46-56 min | Chromatography: Rf and the conditions | Spots at 6.0 cm and 3.2 cm with the front at 8.0 cm give Rf 0.75 and 0.40; comparison requires the same solvent, stationary phase and temperature, and oversized spots distort the value | Students compute both Rf values and list the three conditions |
| 56-60 min | Exit check | Collect three questions and mark at once, labelling errors as unit, ratio or identification condition | Independent work |
03 Teaching script (read it out)
Scene 1: Act 1: one wrong unit spoils everything
Student: 0.480 divided by 2400, so 2.00 x 10 to the minus 4.
Tutor: In what unit?
Student: mol per dm3.
Tutor: Because epsilon carries dm3 mol minus 1 cm minus 1 and l is in cm, so the length units cancel and mol per dm3 is left. Convert l to 0.01 m without converting epsilon and you are out by a factor of a hundred.
Student: What if epsilon is not given?
Tutor: Then the slope of the calibration line replaces epsilon l, because that slope is exactly epsilon l.
Students compute c with the full unit and explain that the slope equals epsilon l.
Scene 2: Act 2: the calibration curve beats the formula
Student: So scale it, 0.360 over 0.240 times 0.100 gives 0.150.
Tutor: Because a straight line through the origin keeps A proportional to c. Once the curve bends at high concentration, interpolate only inside the linear region.
Student: And if the sample had been diluted fivefold?
Tutor: Then 0.150 describes the diluted solution and the original is five times that, 0.750. Do not flip the direction.
Students complete the interpolation and the dilution step, and explain the linear-region limit.
Scene 3: Act 3: Rf plus three conditions
Student: 0.75 and 0.40.
Tutor: Good. If an unknown gives 0.40, is that proof it is the second dye?
Student: No, the conditions must match.
Tutor: Three of them: same solvent, same stationary phase, same temperature, and ideally a known standard on the same plate. Large spots tail and shift the value.
Students write the two Rf values and the three conditions identification needs.
04 Question types and worked steps
| Type | Example | Steps | Answer |
|---|---|---|---|
| Direct use of A = epsilon c l | A 0.480, epsilon 2400, l 1.0 cm | Check units, then c equals A over epsilon l, then attach mol per dm3 | 2.00 x 10 to the minus 4 mol per dm3 |
| Calibration interpolation | 0.100 gives A 0.240, unknown A 0.360 | Plot A against c, confirm it passes the origin, interpolate proportionally | 0.150 mol per dm3 |
| Dilution conversion | Diluted reading 0.150 with a fivefold dilution | Decide the direction, then original equals diluted times the factor | 0.750 mol per dm3 |
| Chromatography Rf | Spots at 6.0 cm and 3.2 cm, front 8.0 cm | Measure from origin to spot centre and to the front, divide, compare under identical conditions | 0.75 and 0.40 |
05 Independent practice (3 questions)
| Question | Answer | What to watch |
|---|---|---|
| A solution has A 0.480 with epsilon 2400 and l 1.0 cm. Find the concentration | 2.00 x 10 to the minus 4 mol per dm3 | Whether students give the unit and cancel cm properly |
| A 0.100 standard reads 0.240 and the sample reads 0.360 after a fivefold dilution. Find the original concentration | 0.150 diluted, so 0.750 in the original | Whether the dilution direction was flipped |
| A front moves 8.0 cm with spots at 6.0 cm and 3.2 cm. Find Rf and state the identification conditions | 0.75 and 0.40, with the same solvent, stationary phase and temperature | Whether conditions are stated alongside the numbers |
06 Common mistakes and what to say
| Mistake | Student writes | Say this |
|---|---|---|
| Mixing units | Writing l as 1.0 m while keeping epsilon at 2400 per cm | Path length and epsilon must share a length unit, so a cm based epsilon pairs with l in cm, otherwise the answer is out by a hundred. |
| Flipping the dilution | Multiplying 0.150 by five and calling it the diluted solution | Dilution lowers concentration, so the original is the diluted value times the factor; write the direction in words before multiplying. |
| Comparing Rf across conditions | Matching an Rf obtained with a different eluent | Rf is not a universal constant, so identification needs the same solvent, stationary phase and temperature with a standard run alongside. |
| Reading beyond the linear range | Plugging A 2.4 into the straight line | Absorbance above roughly 1.5 to 2 departs from linearity, so dilute and remeasure or the concentration is overestimated. |
07 Homework (paper, section and question numbers)
- Secondary chemistry chapter index — Revise the equilibrium and organic chapters before this worksheet
- Chemical equilibrium — Questions 2 to 4 as practice in unit discipline for quantitative work
- Introduction to organic chemistry — Extension: use solvent polarity to explain the order of separation
08 Exit check (last 5 minutes)
| Question | Answer | Decision |
|---|---|---|
| A 0.480 with epsilon 2400 and l 1.0 cm gives which concentration | 2.00 x 10 to the minus 4 mol per dm3 | Correct value plus the unit from epsilon l means pass |
| A fivefold diluted sample reads 0.150. What is the original | 0.750 mol per dm3 | 0.750 means pass; 0.030 means the direction was flipped |
| Which three conditions must match for Rf identification | Same solvent, same stationary phase, same temperature | All three means pass; same paper alone is not enough |
09 Tutor FAQ
Students compute correctly but drop units, so what drill works?
Have them add a line after every answer reading unit from epsilon l and copy the epsilon unit in full. Three repetitions make the habit stick.
Why use a calibration curve when epsilon is available?
Because matrix, pH and temperature shift real absorbances, and a curve built in the same matrix absorbs those systematic effects.
Can chromatography be quantitative?
Yes, with standards and controlled spot size, but school work treats it as identification; routine quantitation uses HPLC or GC.
Find a tutor — freeTutor Registration →