/en-tutor-prep-s6-chemistry-spectrophotometry-chromatography/
/en-tutor-prep-s6-chemistry-spectrophotometry-chromatography/
General Inquiry: info@TutorZone.com.hk
Office Hours: Monday to Saturday - 9:00 AM to 6:00 PM
WhatsApp Monday to Sunday - 24 hours
Hotline: +852 6828 1809
Instant Support: +852 9061 3106

S6 Chemistry | Spectrophotometry and Chromatography Prep Guide (for tutors) | Two formulae, one analytical question

S6 Chemistry | Spectrophotometry and Chromatography Prep Guide (for tutors) | Two formulae, one analytical question

  • 2026-11-17

Marks are lost in analytical questions from units and ratios rather than from unfamiliar formulae. In A = epsilon c l the concentration must be in mol per dm3 and the path length in cm, and mixing either costs orders of magnitude. For chromatography, an Rf only means something at the same solvent, same stationary phase and same temperature.

Objectives — Students can: (1) find a concentration from absorbance and molar absorptivity, with A 0.480, epsilon 2400 and l 1.0 cm giving 2.00 x 10 to the minus 4 mol per dm3; (2) interpolate an unknown on a calibration curve, since 0.100 mol per dm3 gives A 0.240 and a sample with A 0.360 gives 0.150; (3) convert dilution and transmittance, with A 0.480 corresponding to 33.1%; (4) read Rf values of 0.75 and 0.40 and state the three conditions identification requires.

01 Prerequisites (3-minute check)

If any of these fails, fix it before the lesson starts.

Skill Quick check Pass mark
Concentration units Relation between mol per dm3 and mol per cm3 1 mol per dm3 is 1000 times 1 mol per cm3
Proportional reasoning A 0.240 corresponds to 0.100, so what does A 0.360 give 0.150
Significant figures How many figures 0.150 should carry Three, matching the 0.100 given
Chromatography principle Why dyes separate Different adsorption to the stationary phase and solubility in the mobile phase

02 Lesson flow (60 minutes)

Time Stage Tutor does Student does
0-8 min Entry questions What links absorbance and concentration, how do transmittance and absorbance convert, can Rf exceed 1 Oral answers; the tutor writes A = epsilon c l with the three units labelled
8-24 min Act 1: unit discipline in A = epsilon c l With A 0.480, epsilon 2400 and l 1.0 cm, c is A over epsilon l, giving 2.00 x 10 to the minus 4 mol per dm3; the cm cancels against cm to the minus 1 in epsilon Students substitute and write the unit, correcting any wrong unit on the spot
24-36 min Act 2: calibration curve and interpolation Four standards give a straight line of A against c; an unknown with A 0.360 falls between 0.240 and 0.480 and interpolates to 0.150; if the sample was diluted fivefold the original is 0.750 Students interpolate on the graph and state the dilution direction
36-46 min Act 3: transmittance and the useful range A 0.480 gives T equal to 10 to the minus 0.480, which is 0.331 or 33.1%; readings are most reliable between about 0.2 and 0.8, so concentrated samples are diluted Students compute T and explain why dilution is needed
46-56 min Chromatography: Rf and the conditions Spots at 6.0 cm and 3.2 cm with the front at 8.0 cm give Rf 0.75 and 0.40; comparison requires the same solvent, stationary phase and temperature, and oversized spots distort the value Students compute both Rf values and list the three conditions
56-60 min Exit check Collect three questions and mark at once, labelling errors as unit, ratio or identification condition Independent work

03 Teaching script (read it out)

Scene 1: Act 1: one wrong unit spoils everything

Tutor: A equals epsilon c l. With A 0.480, epsilon 2400 and l 1.0 cm, what is c?
Student: 0.480 divided by 2400, so 2.00 x 10 to the minus 4.
Tutor: In what unit?
Student: mol per dm3.
Tutor: Because epsilon carries dm3 mol minus 1 cm minus 1 and l is in cm, so the length units cancel and mol per dm3 is left. Convert l to 0.01 m without converting epsilon and you are out by a factor of a hundred.
Student: What if epsilon is not given?
Tutor: Then the slope of the calibration line replaces epsilon l, because that slope is exactly epsilon l.

Students compute c with the full unit and explain that the slope equals epsilon l.

Scene 2: Act 2: the calibration curve beats the formula

Tutor: A laboratory rarely hands you epsilon but always gives a calibration curve. A 0.100 standard reads 0.240 and the unknown reads 0.360.
Student: So scale it, 0.360 over 0.240 times 0.100 gives 0.150.
Tutor: Because a straight line through the origin keeps A proportional to c. Once the curve bends at high concentration, interpolate only inside the linear region.
Student: And if the sample had been diluted fivefold?
Tutor: Then 0.150 describes the diluted solution and the original is five times that, 0.750. Do not flip the direction.

Students complete the interpolation and the dilution step, and explain the linear-region limit.

Scene 3: Act 3: Rf plus three conditions

Tutor: One spot moves 6.0 cm and another 3.2 cm with the front at 8.0 cm. What are the Rf values?
Student: 0.75 and 0.40.
Tutor: Good. If an unknown gives 0.40, is that proof it is the second dye?
Student: No, the conditions must match.
Tutor: Three of them: same solvent, same stationary phase, same temperature, and ideally a known standard on the same plate. Large spots tail and shift the value.

Students write the two Rf values and the three conditions identification needs.

04 Question types and worked steps

Type Example Steps Answer
Direct use of A = epsilon c l A 0.480, epsilon 2400, l 1.0 cm Check units, then c equals A over epsilon l, then attach mol per dm3 2.00 x 10 to the minus 4 mol per dm3
Calibration interpolation 0.100 gives A 0.240, unknown A 0.360 Plot A against c, confirm it passes the origin, interpolate proportionally 0.150 mol per dm3
Dilution conversion Diluted reading 0.150 with a fivefold dilution Decide the direction, then original equals diluted times the factor 0.750 mol per dm3
Chromatography Rf Spots at 6.0 cm and 3.2 cm, front 8.0 cm Measure from origin to spot centre and to the front, divide, compare under identical conditions 0.75 and 0.40
Sanity check (teach this): Absorbance normally sits between 0 and 2, and anything higher needs dilution; transmittance must lie between 0 and 100 percent, so 33.1% for A 0.480 is sound; molar absorptivity is usually between 10 and 10 to the 5, so a value near 10 to the 8 means cm and m were mixed; Rf stays below 1; a dilution always lowers concentration, so a larger answer means the direction was flipped.

05 Independent practice (3 questions)

Question Answer What to watch
A solution has A 0.480 with epsilon 2400 and l 1.0 cm. Find the concentration 2.00 x 10 to the minus 4 mol per dm3 Whether students give the unit and cancel cm properly
A 0.100 standard reads 0.240 and the sample reads 0.360 after a fivefold dilution. Find the original concentration 0.150 diluted, so 0.750 in the original Whether the dilution direction was flipped
A front moves 8.0 cm with spots at 6.0 cm and 3.2 cm. Find Rf and state the identification conditions 0.75 and 0.40, with the same solvent, stationary phase and temperature Whether conditions are stated alongside the numbers

06 Common mistakes and what to say

Mistake Student writes Say this
Mixing units Writing l as 1.0 m while keeping epsilon at 2400 per cm Path length and epsilon must share a length unit, so a cm based epsilon pairs with l in cm, otherwise the answer is out by a hundred.
Flipping the dilution Multiplying 0.150 by five and calling it the diluted solution Dilution lowers concentration, so the original is the diluted value times the factor; write the direction in words before multiplying.
Comparing Rf across conditions Matching an Rf obtained with a different eluent Rf is not a universal constant, so identification needs the same solvent, stationary phase and temperature with a standard run alongside.
Reading beyond the linear range Plugging A 2.4 into the straight line Absorbance above roughly 1.5 to 2 departs from linearity, so dilute and remeasure or the concentration is overestimated.

07 Homework (paper, section and question numbers)

08 Exit check (last 5 minutes)

Question Answer Decision
A 0.480 with epsilon 2400 and l 1.0 cm gives which concentration 2.00 x 10 to the minus 4 mol per dm3 Correct value plus the unit from epsilon l means pass
A fivefold diluted sample reads 0.150. What is the original 0.750 mol per dm3 0.750 means pass; 0.030 means the direction was flipped
Which three conditions must match for Rf identification Same solvent, same stationary phase, same temperature All three means pass; same paper alone is not enough

09 Tutor FAQ

Students compute correctly but drop units, so what drill works?

Have them add a line after every answer reading unit from epsilon l and copy the epsilon unit in full. Three repetitions make the habit stick.

Why use a calibration curve when epsilon is available?

Because matrix, pH and temperature shift real absorbances, and a curve built in the same matrix absorbs those systematic effects.

Can chromatography be quantitative?

Yes, with standards and controlled spot size, but school work treats it as identification; routine quantitation uses HPLC or GC.

Find a tutor — freeTutor Registration →

A TutorZone lesson-prep guide. Written by the TutorZone team; questions and lesson flow are original and are not taken from any school or publisher material.

Join as a tutor or coach — academic, music, sports, arts, STEM. Free to register. See how it works →