DSE Geography | Energy and Resource Management Lesson-Prep Guide (Tutor Edition) | Mix, Efficiency, Capacity Factor

DSE Geography | Energy and Resource Management Lesson-Prep Guide (Tutor Edition) | Mix, Efficiency, Capacity Factor

  • 2026-11-02

Students hear “renewable” and write “clean and green”, while the question wants capacity factors and unit costs. This lesson drags the topic back to tables and arithmetic.

Objectives — Students can: (1) turn an energy table into fossil and low-carbon shares; (2) use a capacity factor to compute a wind farm annual output and the homes it serves; (3) explain with an efficiency gap why the same kilowatt-hour needs different fuel and carbon.

01 Prerequisites (3-minute check)

If any of these fails, fix it before the lesson starts.

Skill Quick check Pass mark
Energy types What counts as primary energy Fossil, nuclear, renewable
Percentages How to convert an amount to a share Item divided by total
Units How MW differs from MWh Power versus energy, an hour apart

02 Lesson flow (60 minutes)

Time Stage Tutor does Student does
0-8 min Energy mix Add six sources and convert to shares Both groups total 100
8-20 min Efficiency gap One kilowatt-hour from 40% and 60% plant 33.3% fuel saved
20-34 min Capacity factor 100 MW farm at 40% 350400 MWh a year
34-46 min Students compute Same farm at 25% Recompute unaided
46-54 min Policy judgement Two for and two against, each with a figure One figure per reason
54-60 min Exit check Three quick questions All three right

03 Teaching script (read it out)

Scene 1: The mix is a percentage table, not a slogan

Six cells: coal 30, gas 25, oil 20, nuclear 10, renewables 15, total 100.
The three fossil cells add to 75%; the two low-carbon cells to 25%.
Students usually add coal and oil only and forget gas, which is still a fossil fuel: the mix answer always starts with the two shares.

Ask students: why gas still counts as fossil (it burns and emits, only less).

Scene 2: The efficiency gap is where fuel is saved

For one kilowatt-hour, a 40% plant burns 1 / 0.40 = 2.5 units; a 60% plant burns 1 / 0.60 = 1.667 units.
Saving = (2.5 – 1.667) / 2.5 = 33.3%; this line earns more than the phrase “higher efficiency reduces emissions”.
Link it to carbon intensity: coal 0.9 kg per kWh, gas 0.4 kg per kWh, so changing fuel changes emissions.

Ask students: why the saving is not 20% (the denominator is the old plant).

Scene 3: The capacity factor sets real output

A 100 MW farm running 8,760 hours would make 876,000 MWh, but wind does not blow flat out all year.
At a 40% capacity factor the equivalent full-load hours are 3504, giving 350400 MWh a year; at 4000 kWh per home that serves about 87600 homes.
“Wind is unreliable” becomes an answer only when written as “capacity factor 40%, so 60% of the time output is below nameplate”.

Ask students: why solar capacity factors in Hong Kong sit below wind (sun hours and cloud).

04 Question types and worked steps

Type Example Steps Answer
Calculation Energy shares Each item divided by the total 75% fossil
Calculation Annual output Nameplate x 8,760 x capacity factor 350400 MWh
Calculation Fuel saving (old use – new use) / old use 33.3%
Essay Energy policy Reliability, cost, carbon, siting: one line each One figure per line
Sanity check (teach this): Shares must total 100; a total of 99 or 101 means a rounding slip.
A capacity factor lies between 0 and 1; anything above 876,000 MWh is a multiplication error.
Keep the denominator consistent: the old plant, not the new one.
Carbon intensity is kilograms per kWh, not per year, unless multiplied by annual use.

05 Independent practice (3 questions)

Question Answer What to watch
Fossil share (coal 30, gas 25, oil 20) 75% 30 + 25 + 20
Output of 100 MW at 40% capacity factor 350400 MWh 100 x 8,760 x 0.40
Fuel saved from 40% to 60% efficiency 33.3% (2.5 – 1.667) / 2.5

06 Common mistakes and what to say

Mistake Student writes Say this
Counting coal and oil only Fossil 50% Gas burns and emits too; skipping it loses 25 points of share.
Treating MW as MWh “Annual output 100 MWh” MW is power; energy needs an hour attached.
Assuming 100% capacity factor Writing 876,000 MWh A farm is not at full load all year.
Inverting the efficiency sum “Saving 20%” The denominator is the old 2.5 units, not the new 1.667.

07 Homework (paper, section and question numbers)

08 Exit check (last 5 minutes)

Question Answer Decision
Fossil share 75% All three right: next chapter
Annual output at 40% 350400 MWh One wrong: redo the 8,760 idea
Fuel saved 33.3% Two wrong: return to act two

09 Tutor FAQ

Why split fossil from low-carbon?

Mark schemes reward comparison at the mix level, not a list of numbers.

Can a capacity factor exceed 50%?

Yes for offshore wind and hydro, but solar in Hong Kong usually stays below 20%.

Is nuclear renewable?

No; it is low-carbon but fuel-limited, so keep it separate.