IGCSE Biology: Enzymes and the lock-and-key model – Basic paper (Paper 1)
- 2026-11-19
IGCSE Biology: Enzymes and the lock-and-key model – Basic paper (Paper 1)
Ten short-answer items on the nature of enzymes, the lock-and-key model, the effects of temperature and pH, and basic average-rate calculations.
Enzymes and the lock-and-key model: key points Enzymes are protein catalysts whose active site fits only a specific substrate; temperature or pH away from the optimum denatures them and lowers the rate. Answers and one-line notes follow each item.
01 Paper details (check answers afterwards)
| Item | Detail |
|---|---|
| Questions | 10 |
| Suggested time | 25 |
| Difficulty mix | Foundation 4 · Intermediate 2 · Challenge 2 · Error redo 2 |
| Chapter | Chapter: IGCSE Biology: Enzymes and the lock-and-key model |
| Level | Basic |
02 Questions (10 items)
- FoundationTo which group of substances do enzymes belong, and are they used up after the reaction?
- FoundationIn the lock-and-key model, what do the lock and the key stand for?
- FoundationWhy does one enzyme usually catalyse only one reaction?
- FoundationWhat is the approximate optimum temperature of human enzymes, and why does the rate fall well above it?
- IntermediateAn experiment collects 30 cubic centimetres of gas in 60 seconds. What is the average rate?
- IntermediateA second set-up collects 120 cubic centimetres in 2 minutes. What is the average rate in cubic centimetres per second?
- ChallengeAn enzyme is most active at pH 2 and almost inactive at pH 7. What does this show?
- ChallengeWhen temperature rises from 20 to 30 degrees the rate goes from 4 to 8 cubic centimetres per minute. What is Q10?
- Error redoA student writes that enzymes are used up in the reaction and must be constantly replaced. What is wrong?
- Error redo45 cubic centimetres of gas are collected in 90 seconds, but a student answers 2 cubic centimetres per second. What is the correct rate?
03 Answers and one-line notes
| # | Answer | One-line note |
|---|---|---|
| 1 | Enzymes are proteins and act as biological catalysts; they are not used up and can be reused. | An enzyme lowers the energy needed for the reaction but keeps its own structure, so it can work again. |
| 2 | The lock is the enzyme active site and the key is the substrate. | The substrate shape must be complementary to the active site before binding can occur. |
| 3 | Because its active site is complementary to only one substrate, a property called specificity. | Specificity comes from the active-site shape, so other molecules cannot fit and are not catalysed. |
| 4 | About 37 degrees Celsius; high temperature denatures the enzyme so the active site changes shape. | After denaturation the active site shape is permanently altered, so the rate collapses. |
| 5 | 0.5 cubic centimetres per second. | Rate is product divided by time: 30 divided by 60 gives 0.5. |
| 6 | 1.0 cubic centimetre per second. | Convert 2 minutes to 120 seconds, then 120 divided by 120 gives 1.0. |
| 7 | Its optimum pH is about 2, as with pepsin; moving away from the optimum denatures it. | Too much acid or alkali alters the charge and shape of the active site, so the substrate cannot bind. |
| 8 | 2.0. | Q10 is the new rate divided by the old rate: 8 divided by 4 gives 2.0. |
| 9 | Enzymes are not used up and are reusable; it is the substrate that runs out. | The enzyme keeps its structure after the reaction, so one molecule can catalyse many times. |
| 10 | 0.5 cubic centimetre per second. | Divide the amount by the time: 45 divided by 90 gives 0.5, not the other way round. |
04 What to do after marking
- After marking, redo only the wrong items and write down which step went wrong (formula, unit, or misread number).
- Repeat the same item two days later; move to the next paper only when both attempts are correct.
- Parents only need the answer and note columns; there is no need to explain every item.
Download the full ten-item paper as a PDF, answers and notes included.Tutor Registration →
Questions and answers are written originally by the TutorZone team and are not taken from any school, publisher or examination authority paper. Every value is checked by computer.



