/en-tutor-prep-s2-geography-energy-resources-renewable-mix-practice-4/
/en-tutor-prep-s2-geography-energy-resources-renewable-mix-practice-4/
General Inquiry: info@TutorZone.com.hk
Office Hours: Monday to Saturday - 9:00 AM to 6:00 PM
WhatsApp Monday to Sunday - 24 hours
Hotline: +852 6828 1809
Instant Support: +852 9061 3106

S2 Geography Energy resources Paper 4: retry practice

S2 Geography Energy resources Paper 4: retry practice

  • 2026-11-18

S2 Geography Energy resources Paper 4: retry practice

Ten retry items correcting errors on energy classification, night-time solar output, installed capacity, percentage bases, capacity factor and potential energy units.

Ten misconceptions taken apart Wrong percentage bases, treating nuclear as renewable and confusing capacity factor with running time are all corrected and rebuilt with the right method.

01 Paper details (check answers afterwards)

Item Detail
Questions 10
Suggested time 25
Difficulty mix Foundation 4 · Intermediate 2 · Challenge 2 · Error redo 2
Chapter Chapter: S2 Geography: Energy resources and the renewable mix
Level Retry practice

02 Questions (10 items)

  1. FoundationCoal is a fossil fuel, so which energy category does it belong to?
  2. FoundationWhat is the output of solar panels at night?
  3. FoundationIs the installed capacity of 20 turbines rated 2.5 MW each equal to 5 MW or 50 MW?
  4. FoundationIf 1 000 of 4 000 GWh is renewable, is the share 25 per cent or 40 per cent?
  5. IntermediateGas at 0.4 kg per kWh emits 55.6 per cent less than coal at 0.9 kg. If someone answers 125 per cent, what went wrong?
  6. IntermediateNuclear power is a low-carbon source, but does that make it renewable?
  7. ChallengeDoes a 30 per cent capacity factor mean the turbine only turns 30 per cent of the time?
  8. ChallengeWhen computing pumped storage potential energy, is the mass of one cubic metre of water 1 000 kg or 100 kg?
  9. Error redoIs the potential energy of 1 000 cubic metres lifted 100 metres equal to 272.5 kWh or 272.5 MWh?
  10. Error redoEmissions fall from 0.9 to 0.4 kg per kWh. Which figure should be the denominator for the percentage cut?

03 Answers and one-line notes

# Answer One-line note
1 Non-renewable. Coal formed from ancient plants over geological time, so it is used far faster than it forms.
2 Zero, so daytime storage is needed. Sunlight is the only energy source for solar panels, so there is no generation without it at night.
3 50 MW. 20 times 2.5 is 50, so the rating of a single turbine must not be used alone.
4 25 per cent. 1 000 divided by 4 000 is 0.25, with total city demand as the denominator.
5 The new figure was used as the base. 0.9 minus 0.4 divided by 0.9 is 55.6 per cent, so the original coal figure must be the base.
6 No. Uranium ore is finite, so nuclear is low carbon yet still non-renewable.
7 No. Capacity factor compares actual output with full-load output; turbines turn most of the time but at lower power.
8 1 000 kg. Water density is 1 000 kg per cubic metre, so mass must be converted to kilograms first.
9 272.5 kWh. 9.81 times ten to the eighth joules divided by 3.6 million is 272.5 kWh, a thousand times smaller than MWh.
10 0.9, the original figure. A percentage decrease always uses the original value as the base, so answering 20 per cent uses the wrong denominator.

04 What to do after marking

  • After marking, redo only the wrong items and write down which step went wrong (formula, unit, or misread number).
  • Repeat the same item two days later; move to the next paper only when both attempts are correct.
  • Parents only need the answer and note columns; there is no need to explain every item.

Download the full ten-item paper as a PDF, answers and notes included.Tutor Registration →

Questions and answers are written originally by the TutorZone team and are not taken from any school, publisher or examination authority paper. Every value is checked by computer.

Join as a tutor or coach — academic, music, sports, arts, STEM. Free to register. See how it works →