Junior Geography | Energy and Resources Prep Guide (for tutors) | Fuel Mix, Generation and Renewables
- 2026-11-18
Students answer use more solar and stop when asked how much a three kilowatt roof generates in a year or how much carbon that avoids, and they read two million kilowatts of installed capacity as annual output. This lesson turns energy questions into four calculations: fuel mix, generation, capacity factor and carbon saved.
01 Prerequisites (3-minute check)
If any of these fails, fix it before the lesson starts.
| Skill | Quick check | Pass mark |
|---|---|---|
| Percentages | Twenty-five percent of forty-five thousand | Eleven thousand two hundred and fifty |
| Unit conversion | One gigawatt hour equals how many megawatt hours | One thousand megawatt hours |
| Order of operations | Does multiplying a percentage before a time change the answer | No, but write the units at every step |
02 Lesson flow (60 minutes)
| Time | Stage | Tutor does | Student does |
|---|---|---|---|
| 0-6 min | Opening probe | Ask whether two thousand megawatts of capacity means two thousand megawatt hours a year | Write a judgement, revisit at the end |
| 6-18 min | Fuel mix percentages | Model generation per fuel from total and shares | Compute the coal and gas lines |
| 18-32 min | Capacity factor | Model capacity times factor times 8,760 hours | Run a wind farm example |
| 32-44 min | Household solar | Scale daily output to a year and to carbon | Compute a three kilowatt system |
| 44-54 min | Target and payback | Model the renewable gap and the payback period | Compute gap and payback |
| 54-60 min | Exit check | Collect and mark two items, name the error type | Work independently |
03 Teaching script (read it out)
Scene 1: Percentages split a total, they do not describe it
Put the units into everyday terms: forty-five thousand gigawatt hours is forty-five million megawatt hours, which over three hundred and sixty-five days averages twelve thousand three hundred and twenty-nine megawatt hours a day. A student with that number stops being intimidated by the word gigawatt.Flag the classic error: a percentage of generation is not a percentage of capacity. If the question gives capacity, the share cannot be applied to it; a capacity factor has to be found first.Model the table: fuel, share, generation, check. Four columns per line, and nothing gets dropped.
Students do: fill the four-column table for three fuels and write the total.
Students say: why a total that does not match the overall figure proves an arithmetic error.
Scene 2: Capacity is not output, a capacity factor sits between
Wind farm: two thousand megawatts of capacity, capacity factor thirty percent, eight thousand seven hundred and sixty hours a year, so generation is two thousand times zero point three times eight thousand seven hundred and sixty, which is five million two hundred and fifty-six thousand megawatt hours, or five thousand two hundred and fifty-six gigawatt hours. Work it backwards: five thousand two hundred and fifty-six divided by two thousand times eight thousand seven hundred and sixty returns thirty percent, so the formula is consistent.Explain why the factor is below one: wind does not blow constantly, solar produces nothing at night, and units need maintenance. Coal can be dispatched and reaches above eighty percent; wind and solar usually sit between twenty and thirty.Scale down to a household: a three kilowatt system with three and a half equivalent sun hours makes ten point five kilowatt hours a day, which over three hundred and sixty-five days is three thousand eight hundred and thirty-two point five kilowatt hours. No capacity factor is needed here because the sun hours already carry the discount.Watch units: a kilowatt is power, a kilowatt hour is energy, and only the second one belongs in an annual total.
Students do: compute the wind farm output and check it backwards.
Students say: why equal capacity gives wind and coal such different annual output.
Scene 3: Carbon and payback close the loop
Model: coal emits zero point nine tonnes of carbon dioxide per megawatt hour and gas zero point four. Coal at eleven thousand two hundred and fifty gigawatt hours is eleven point two five million megawatt hours, times zero point nine gives ten point one two five million tonnes; gas at twenty-two thousand five hundred gigawatt hours times zero point four gives nine million tonnes; together nineteen point one two five million tonnes.Household solar: three thousand eight hundred and thirty-two point five kilowatt hours a year at half a kilogram per kilowatt hour avoids one thousand nine hundred and sixteen kilograms, about one point nine two tonnes. An installation at sixty thousand dollars saving one dollar ten per kilowatt hour earns four thousand two hundred and fifteen dollars seventy-five a year, so payback is about fourteen point two years.Then the policy target: a renewable share of seven point five percent of forty-five thousand gigawatt hours is three thousand three hundred and seventy-five gigawatt hours. If the current share is two percent, the gap is five point five percentage points, or two thousand four hundred and seventy-five gigawatt hours, and both figures must appear in the answer.Close with one rule: every energy answer carries a unit, and an answer without one is unfinished.
Students do: compute carbon avoided and the payback period for the household system.
Students say: is a fourteen-year payback long, and what would you compare it with.
04 Question types and worked steps
| Type | Example | Steps | Answer |
|---|---|---|---|
| Fuel mix | Total 45,000 gigawatt hours, coal 25, gas 50, nuclear 25 percent | Multiply each share, then check the total | Coal and nuclear 11,250 each, gas 22,500 gigawatt hours |
| Capacity factor | Wind farm of 2,000 megawatts at 30 percent | Capacity times factor times 8,760 hours | 5,256 gigawatt hours, that is 5.256 million megawatt hours |
| Household generation and carbon | Three kilowatts, three and a half sun hours | Daily output times 365, then times the emission factor | 3,832.5 kilowatt hours a year, about 1.92 tonnes avoided |
| Target gap | Target 7.5 percent against 2 percent now | Target share times total minus current share times total | A gap of 5.5 points, that is 2,475 gigawatt hours |
05 Independent practice (3 questions)
| Question | Answer | What to watch |
|---|---|---|
| Fuel mix | Total 50,000 gigawatt hours, coal 30, gas 45, nuclear 25 percent | Check each share is multiplied and the total reconciles |
| Capacity factor | 1,500 megawatts at 25 percent for a year | Check the 8,760 hours and the answer 3,285 gigawatt hours |
| Payback | Installation 45,000 dollars, annual saving 3,000 | Check annual saving in the denominator, answer 15 years |
06 Common mistakes and what to say
| Mistake | Student writes | Say this |
|---|---|---|
| Capacity treated as output | Saying a 2,000 megawatt wind farm makes 2,000 megawatt hours a year | Two thousand megawatts is an hourly ceiling; multiply by the factor and by 8,760 hours. |
| Share applied to capacity | Multiplying the fuel share by installed capacity | The share belongs to generation, not capacity; multiply the total generation instead. |
| Power and energy mixed | Writing that the roof makes ten point five kilowatts a day | Kilowatts are power and kilowatt hours are energy; add the hour before calling it energy. |
| Carbon without a unit | Writing that the system avoids one thousand nine hundred and sixteen | One thousand nine hundred and sixteen of what? Put kilograms or tonnes before submitting. |
07 Homework (paper, section and question numbers)
- Geography chapter index — All chapters for this subject
- Prep guide master index — Matching chapters in other subjects
- Redo this chapter — Practice items 1, 2 and 3: fuel mix, capacity factor, payback
08 Exit check (last 5 minutes)
| Question | Answer | Decision |
|---|---|---|
| Capacity versus output | Capacity times factor times time gives energy | Treating capacity as output means act two again |
| Units | Kilowatt hours for energy, kilowatts for power | Mixing them means rewriting two answers |
| Target gap | Target share minus current share, times total | Points without gigawatt hours means one more sum |
09 Tutor FAQ
What if students have not met capacity factor
Describe it as the most a plant could make in an hour against what it really makes, then contrast wind with coal; no derivation is needed.
Must they memorise a territory fuel mix
No. They must be able to split a total by shares and say whether coal or gas emits more per unit.
Are calculators allowed
Yes, but every step needs its formula and unit written down, because marks sit in the method rather than the final figure.
Find a tutor — freeTutor Registration →
A TutorZone lesson-prep guide. Written by the TutorZone team; questions and lesson flow are original and are not taken from any school or publisher material.



