Junior Science | Household Electricity and Bill Calculation Prep Guide (for tutors) | Power, Current and Safety

Junior Science | Household Electricity and Bill Calculation Prep Guide (for tutors) | Power, Current and Safety

  • 2026-11-18

Students can recite that power is voltage times current, then write that a kettle used 2,200 units. The formula was never the problem: watts must become kilowatts and minutes must become hours. This lesson fixes both conversions against one bill.

Objectives — Students can: (1) divide power by voltage to get current, using 220 volts as the Hong Kong mains voltage; (2) convert watts to kilowatts and minutes to hours, multiply to get kilowatt hours, then multiply by the tariff; (3) add appliance power, convert to current and judge whether a 20 ampere breaker holds; (4) explain earthing, fuses and breakers, and why water is never used on an electrical fire.

01 Prerequisites (3-minute check)

If any of these fails, fix it before the lesson starts.

Skill Quick check Pass mark
Division and units 2,200 watts at 220 volts, what current 10 amperes, because watts divided by volts gives amperes
Time conversion How many hours is ten minutes Ten divided by sixty, one sixth, about 0.167 hours
Decimals and money 0.367 kilowatt hours at 1.2 dollars each 0.44 dollars, forty-four cents

02 Lesson flow (60 minutes)

Time Stage Tutor does Student does
0-6 min Opening probe Ask the cost of boiling a 2,200 watt kettle for ten minutes Write an estimate, revisit at the end
6-18 min Power, voltage, current Model three currents: 2,200, 3,000 and 60 watts Compute one at 1,100 watts
18-32 min Kilowatt hours and cost Convert watts to kilowatts and minutes to hours, then multiply by the tariff Compute kettle and air-conditioner costs
32-42 min Breakers and fuses Convert a total load to current and compare with 20 amperes Judge whether one more appliance trips the breaker
42-52 min Electrical safety Cover earthing, double insulation, overload, water and electricity Order a response to a shock
52-60 min Exit check Collect two answers and point at the unit error Work independently

03 Teaching script (read it out)

Scene 1: Three appliances, three currents

Act one connects power to current. The commonest error is assuming a bigger wattage is automatically the danger, when the current is what heats the wiring, and current comes from power divided by voltage. Write the formula: power equals voltage times current, so current equals power divided by voltage. Put 220 volts in the corner of the board and point at it in every later question. Three examples: a 2,200 watt kettle gives 2,200 divided by 220, ten amperes; a 3,000 watt heater gives 13.6 amperes; a 60 watt lamp gives 0.27 amperes. Then make it domestic: a 13 ampere plug already carries a heater at 13.6 amperes, so adding a 1,000 watt hairdryer at 4.5 amperes brings the total to 18.1 and the plug and extension board warm up. That is why a loaded extension board is not a superstition but an addition.

Students do: compute the current of a 1,100 watt rice cooker.
Students say: why the same 2,200 watts draws twice the current in a 110 volt country.

Scene 2: Kilowatt hours: two conversions

Act two is entirely about the bill. Almost every wrong bill answer dies at one of two conversions, watts to kilowatts or minutes to hours, so both get written down with units on every line. The formula: energy in kilowatt hours equals power in kilowatts times time in hours. 2,200 watts is 2.2 kilowatts; ten minutes is ten sixtieths of an hour, 0.1667 hours; the product is 0.367 kilowatt hours. Multiply by the tariff, say 1.2 dollars per kilowatt hour, to get 0.44 dollars, forty-four cents. Students are surprised the kettle costs forty-four cents, and that surprise is the moment an estimate gets corrected. Then a larger case: a 1,500 watt air-conditioner for eight hours a day over thirty days is 1.5 times 8 times 30, which is 360 kilowatt hours; at 1.5 dollars each the bill is 540 dollars. Placed beside forty cents, the two numbers explain why cooling dominates a bill. Add standby power: five watts for twenty-four hours over thirty days is 3.6 kilowatt hours, about 4.32 dollars. Small alone, which is why the point is to multiply by ten appliances rather than to exaggerate one.

Students do: cost a 60 watt fan running five hours a day for thirty days at 1.2 dollars.
Students say: why bills use kilowatt hours instead of joules.

Scene 3: Breakers, earthing and shock

Act three attaches the arithmetic to safety devices. A breaker does not limit use; it prevents overheating and fire. Start with current: a circuit carrying 3,200 watts draws 3,200 divided by 220, which is 14.55 amperes, leaving 5.45 amperes of headroom under a 20 ampere breaker, roughly 1,200 watts. Adding a 1,500 watt heater trips it, and that trip is design working, not a fault. Three devices: a fuse is a metal link that melts and breaks the circuit under excess current; a breaker is a reusable switch that trips on overload; an earth wire connects a metal casing to the ground so leakage flows to earth instead of through a person. Tie every rule to a physical reason: never touch switches with wet hands, never use water on an electrical fire because water conducts and the rescuer becomes the path, never push metal into a socket, keep plugs dry, never run cable under a door or a heavy object. Response order for a shock: switch off the supply or separate the casualty with an insulated object, then call for help and give first aid, never pull the casualty with bare hands. This is the same logic as risk scoring in the S1 lesson: remove the hazard before treating the person.

Students do: compute the current of a 3,200 watt circuit and judge a 1,500 watt addition.
Students say: how an earth wire protects a user.

04 Question types and worked steps

Type Example Steps Answer
Current A 3,000 watt heater at 220 volts Power divided by voltage, with amperes as the unit 13.6 amperes
Energy cost Air-conditioner 1,500 watts, 8 hours a day, 30 days, 1.5 dollars per unit Watts to kilowatts, multiply hours, multiply tariff 360 kilowatt hours, 540 dollars
Overload decision Circuit at 3,200 watts, breaker at 20 amperes Compute 14.55 amperes, then the headroom Safe, 5.45 amperes left, about 1,200 watts
Safety device A washing machine with a metal casing leaks Earth wire carries leakage to ground, breaker cuts supply Earthing protects the user, the breaker isolates the supply
Sanity check (teach this): Reasonable-check list: current is always a smaller number than power, because 220 divides it; a current of 2,200 amperes means the division was skipped; the bill unit is the kilowatt hour, so watts as an answer is wrong; a kilowatt hour figure is usually smaller than the wattage because the time is under one hour or only a few hours; minutes must become hours, and treating ten minutes as ten hours inflates the answer sixty times; a bill must match the appliance scale, forty-four cents for a kettle and hundreds of dollars for cooling; a breaker rating must exceed the normal current or it trips at switch-on; a safety answer of do not use electricity is empty, so demand a specific action.

05 Independent practice (3 questions)

Question Answer What to watch
Current A 1,100 watt rice cooker Check five amperes with the unit stated
Energy cost A 60 watt fan, 5 hours a day for 30 days at 1.2 dollars Check nine kilowatt hours and 10.8 dollars
Overload 3,200 watts plus a 1,500 watt heater Check a total near 21.4 amperes and a trip

06 Common mistakes and what to say

Mistake Student writes Say this
Skipping the division Write a current of 2,200 amperes Watts must be divided by 220 to give amperes; a 2,200 ampere current would melt the cable itself.
Minutes as hours Write 22 kilowatt hours Ten minutes is one sixth of an hour, not ten hours; the unit error multiplies the answer by sixty.
Wrong bill unit Write a cost of 0.367 watts Kilowatt hours measure energy and dollars measure money; both belong in the answer.
Vague safety answer Write be careful with electricity Name the action: switch off the supply, use an insulated object, never pull the casualty, never use water on an electrical fire.

07 Homework (paper, section and question numbers)

08 Exit check (last 5 minutes)

Question Answer Decision
Current formula Power divided by voltage, in amperes A missed division means act one again
Two conversions Watts to kilowatts, minutes to hours Any slip means three more items
Safety devices Earthing, fuse and breaker each do a different job Caution alone means act three again

09 Tutor FAQ

What if students have not met electrical power

Introduce it as how many 220 volt currents an appliance needs, and the formula appears without any need for charge.

Why 220 volts in Hong Kong

A higher voltage means less current for the same power and thinner cable, at the cost of a worse shock, which is why safety devices matter more.

Must students memorise the tariff

No, the tariff is always given; what must be memorised is the two conversions and the units.

Find a tutor — freeTutor Registration →