/en-tutor-prep-s3-physics-energy-resources-power-station/
/en-tutor-prep-s3-physics-energy-resources-power-station/
General Inquiry: info@TutorZone.com.hk
Office Hours: Monday to Saturday - 9:00 AM to 6:00 PM
WhatsApp Monday to Sunday - 24 hours
Hotline: +852 6828 1809
Instant Support: +852 9061 3106

Junior Physics | Energy Resources and Power Stations: Tutor Prep Guide | Conservation before efficiency

Junior Physics | Energy Resources and Power Stations: Tutor Prep Guide | Conservation before efficiency

  • 2026-11-22

Every student can say a power station burns coal to make electricity, but ask how much fuel a 600 megawatt station burns and most answer 600 megawatts, because nobody has made them divide by efficiency.

Objectives — By the end the student can: state conservation of energy and define efficiency, then show that a 600 megawatt station at 40 percent efficiency needs 1500 megawatts of input with 900 megawatts leaving as waste heat; convert power to energy and get 14400 megawatt hours a day, or 51840 gigajoules; use 0.9 kilograms of carbon dioxide per kilowatt hour to get about 12960 tonnes a day; and compare renewables, where a 2 megawatt turbine at a 0.30 capacity factor averages 0.60 megawatts and 5256 megawatt hours a year, so about 1000 are needed to match one 600 megawatt station.

01 Prerequisites (3-minute check)

If any of these fails, fix it before the lesson starts.

Skill Quick check Pass mark
Power and energy A 1 kilowatt appliance runs 2 hours, how much energy? 2 kilowatt hours
Percentages What fraction of the input is useful at 40 percent? 0.40
Unit conversion How many joules in one kilowatt hour? 3.6 megajoules

02 Lesson flow (60 minutes)

Time Stage Tutor does Student does
0-6 min Prior check Power times time, percentages, kilowatt hours Two of three correct before moving on
6-16 min Conservation and efficiency Input equals useful output plus waste Student writes 600 over 0.4
16-26 min The energy chain Chemical, heat, steam, turbine, electricity Student names where the losses sit
26-36 min Fuel and emissions 1500 megawatts in, 12960 tonnes of carbon dioxide a day Student converts daily energy
36-46 min Capacity factors 2 megawatts times 0.30 averages 0.60 megawatts Student compares annual output
46-54 min Counting solar panels 400 watt panel, 4 hours sun, 1.60 kilowatt hours Student gets 8 panels
54-60 min Exit check Ask why efficiency can never be 100 percent Waste heat is unavoidable

03 Teaching script (read it out)

Scene 1: Draw the chain in five boxes

Do not start with fuel. Start with the chain: chemical energy in fuel, heat from combustion, kinetic energy in steam, mechanical energy at the turbine shaft, electrical energy from the generator. Put a percentage beside each arrow and the student finds the losses themselves, usually at the condenser dumping heat into cooling water.

Efficiency is one expression: useful output over total input. So 600 megawatts at 40 percent needs 600 divided by 0.4, which is 1500 megawatts of input, with 900 megawatts wasted. Make the student say the ratio out loud: three fifths of the energy goes up the cooling tower.

Add the thermodynamic reality: efficiency can never reach 100 percent because a heat engine needs a temperature difference and must reject heat. That sentence also explains why the white plume from a cooling tower is not pollution but the price of efficiency.

Student must say: a plant at 40 percent efficiency takes 100 megawatts of fuel, how much is wasted?

Scene 2: Scale: energy, emissions, households

Power times time gives energy. 600 megawatts for 24 hours is 14400 megawatt hours, and multiplying by 3.6 gives 51840 gigajoules. Insist on the units being written, because exam questions set traps exactly at this conversion.

Emissions are a multiplication: 0.9 kilograms per kilowatt hour, so 14400 megawatt hours is 14400000 kilowatt hours, giving 12960 tonnes a day and 365 times that in a year. Let the student press the keys; the shock of a ten thousand tonne daily figure is the point.

Close with a household comparison: a home using 12 kilowatt hours a day means one 600 megawatt station at full load serves about 1.2 million homes. That is why a city needs several stations, and why saving one kilowatt hour removes 0.9 kilograms of carbon dioxide rather than being a slogan.

Student must say: 14400 megawatt hours a day is how many gigajoules?

Scene 3: Renewables are counted by capacity factor, not by the nameplate

A 2 megawatt turbine does not deliver 2 megawatts, because the wind varies. At a 0.30 capacity factor the average is 0.60 megawatts, so over 8760 hours it produces 5256 megawatt hours. Set that against the coal plant: 14400 times 365 is 5256000 megawatt hours, so about 1000 turbines are needed.

Let the student reach that conclusion by calculation. Told once, they do not believe it; calculated once, they understand why wind needs backup capacity and storage rather than being a straight swap.

Solar follows the same logic: a 400 watt panel with 4 effective sun hours gives 1.60 kilowatt hours, so a 12 kilowatt hour home needs 8 panels. Students then ask about night time on their own, which is exactly the door into storage and grid dispatch for the next lesson.

Student must say: why is a 2 megawatt turbine not equivalent to 2 megawatts of coal capacity?

04 Question types and worked steps

Type Example Steps Answer
Input power Output 600 megawatts, efficiency 0.40 Input equals output over efficiency 1500 megawatts
Waste heat Input 1500 megawatts, output 600 Input minus output 900 megawatts
Daily energy 600 megawatts for 24 hours Power times time 14400 megawatt hours
Emissions 14400 megawatt hours at 0.9 kilograms per kilowatt hour Kilowatt hours times factor 12960 tonnes
Sanity check (teach this): Three sanity checks: efficiency below 1 means input power exceeds output, so an input smaller than the output means the division was done backwards; waste heat normally exceeds half the input, so a tenth means the efficiency figure is wrong; and a capacity factor never exceeds 1, so an average output above the nameplate is impossible.

05 Independent practice (3 questions)

Question Answer What to watch
Find efficiency Input 500 megawatts, output 180 0.36, or 36 percent
Annual output Average 0.60 megawatts 5256 megawatt hours
Panel count 18 kilowatt hours a day, 1.6 per panel 12 panels

06 Common mistakes and what to say

Mistake Student writes Say this
Using output as input Answering that a 600 megawatt station burns 600 megawatts of fuel Only the efficiency fraction becomes electricity. Divide first to get 1500 megawatts, then multiply by time; skipping this guarantees a wrong answer.
Forgetting the megawatt hour conversion Answering that daily energy is 14400 joules One kilowatt hour is 3.6 megajoules, so 14400 megawatt hours is 51840 gigajoules. Write the unit before the number.
Confusing capacity factor with efficiency Answering that a turbine is 30 percent efficient Capacity factor is actual annual output over the theoretical full-load output, a statement about wind. Efficiency is about conversion losses. They are not interchangeable.
Assuming zero emissions means zero cost Answering that wind power has no drawbacks Intermittency, land use, noise and backup capacity all cost money. A full-mark answer states benefits and limits; one side alone is an incomplete analysis.

07 Homework (paper, section and question numbers)

08 Exit check (last 5 minutes)

Question Answer Decision
Efficiency Useful output over input, always below 1 Saying 100 percent is possible means redoing waste heat
Energy conversion One kilowatt hour is 3.6 megajoules Multiplying by 1000 alone drops the hour
Capacity factor Actual annual output over full-load output Treating it as efficiency means redoing the turbine question

09 Tutor FAQ

Why is power station efficiency only about 40 percent

A heat engine is limited by its working temperatures, so only part of the combustion heat becomes work in the steam and the rest must be rejected at the condenser. With boiler and pipe losses, large fossil plants sit between 35 and 45 percent.

Why talk about capacity factor for wind

Wind speed varies, so a turbine cannot run at full output all year. The capacity factor converts nameplate power into realistic average output, which is what makes a fair comparison with coal; onshore wind is typically 25 to 40 percent.

Are renewables really zero emission

Operation is close to zero, but manufacturing, transport, installation and decommissioning carry a carbon cost. Life-cycle emissions are still far below fossil fuels, so the conclusion holds, but zero is not the same as nothing.

Find a tutor — freeTutor Registration →

A TutorZone lesson-prep guide. Written by the TutorZone team; questions and lesson flow are original and are not taken from any school or publisher material.

Join as a tutor or coach — academic, music, sports, arts, STEM. Free to register. See how it works →