Junior Science | Earth Resources and Renewable Energy Guide (Teacher Edition) | Classification, Generation Maths, Carbon Intensity

Junior Science | Earth Resources and Renewable Energy Guide (Teacher Edition) | Classification, Generation Maths, Carbon Intensity

  • 2026-11-18

Students answer renewable energy with solar and wind, but cannot say why a grid running forty percent on gas is still called dirty. Two questions have to be separated: will the resource run out, and how much carbon does each unit of electricity emit. One is a stock question, the other a carbon intensity question, and neither substitutes for the other.

Objectives — Students can: (1) sort resources as renewable or non-renewable and explain why nuclear sits outside both labels; (2) compute annual output from solar (power times sun hours), wind (capacity times capacity factor times 8760) and hydro (rho g h Q eta); (3) find the average carbon intensity of a fuel mix and the annual emissions, and compare gas with coal; (4) size a transition gap, from 1 percent to 7.5 percent, and state why enough electricity and clean enough electricity are two questions.

01 Prerequisites (3-minute check)

If any of these fails, fix it before the lesson starts.

Skill Quick check Pass mark
Power and energy One kilowatt for one hour, how much energy One kilowatt hour, which is 3.6 million joules
Percentages Forty percent of electricity from gas, what fraction is that 40 percent, or 0.4
Density and potential energy Water falling 100 metres, where does the energy come from Gravitational potential energy mgh becomes kinetic energy and turns the turbine

02 Lesson flow (60 minutes)

Time Stage Tutor does Student does
0-6 min Opening probe What actually burned to charge your phone Write one fuel, revisit at the end
6-16 min Classification Four boxes: renewable, non-renewable, nuclear, waste heat recovery Draw the diagram with three examples each
16-30 min Three generation formulas Wind, solar and hydro once each, with units cancelling Work out a 3 MW turbine year
30-42 min Carbon intensity Coal 0.9, gas 0.4, nuclear 0 kilograms per unit, then weight Find 425 grams and 17 Mt
42-54 min The transition gap From 1 to 7.5 percent, how many 3 MW turbines Find 2.6 TWh and 330 turbines
54-60 min Exit check Collect three answers and name the common confusion Work independently

03 Teaching script (read it out)

Scene 1: Classification is two questions, not a list

Act one sets criteria; without them students file nuclear under renewable because it emits no carbon at the plant. Two criteria. First, does it replenish on a human timescale, which decides renewable or not. Second, how much carbon per unit of electricity, which is carbon intensity. Solar, wind, water, geothermal, biomass and tidal are renewable. Coal, oil and gas are fossil and non-renewable. Nuclear fission runs on uranium, a finite mineral, so it is non-renewable, yet its carbon intensity is very low, which is exactly why the two criteria must stay separate.
Add the case students miss: biomass emits carbon when burned but the plant absorbed the same carbon while growing, so what counts is the net figure, and renewability depends on replanting.

Include waste heat: a plant converts about forty percent of fuel into electricity and the rest leaves as heat, so district cooling or seawater heating makes the same fuel do more useful work.
Students do: draw the four box diagram with two examples and a rough carbon intensity each.
Students say: why nuclear is low carbon yet still non-renewable.

Scene 2: Three formulas with units that cancel

Act two turns renewable energy from a slogan into numbers a student can audit. Solar: a 5 kW system with 3.2 effective sun hours makes 16 kWh a day and 5,840 kWh a year. At 90,000 dollars installed and 1.2 dollars saved per unit, the annual saving is 7,008 dollars and the payback is 12.8 years, which is why subsidies exist.
Wind: a 3 MW turbine at a 0.30 capacity factor makes 3 times 0.30 times 8,760, which is 7,884 MWh a year, enough for about 1,752 households using 4,500 kWh each. Capacity factor is the key idea: a turbine is not at full output all year, roughly thirty percent on average.
Hydro: 100 metres of head, 50 cubic metres per second and 85 percent efficiency give rho g h Q eta, which is 1000 times 9.81 times 100 times 50 times 0.85, about 41.7 MW. The same formula answers siting: doubling flow doubles power, doubling head doubles power, so what matters is how high the water starts, not how wide the river looks.

Put the three on one page: solar uses panel area, wind uses swept area with wind speed cubed, hydro uses head and flow. Different independent variables explain different siting choices.
Students do: compute a 5 MW turbine at the same capacity factor, which is 13,140 MWh.
Students say: why doubling wind speed multiplies power by roughly eight.

Scene 3: Carbon intensity and the gap: two separate lines

Act three makes energy policy two calculable lines, which is what lets students judge a news claim. Carbon intensity: with 40 TWh a year, coal at 25 percent and 0.9 kilograms per unit, gas at 50 percent and 0.4, nuclear at 25 percent and zero, the weighted average is 425 grams per unit and annual emissions are 17 million tonnes. Switching all coal to gas lowers the average to 400 grams, only one million tonnes less, which is why gas is a bridge and not a destination.
The gap: going from 1 to 7.5 percent renewable is 6.5 percentage points, 2.6 TWh, and at 7,884 MWh per turbine that is about 330 turbines. Once that number is on the board, the discussion moves from panels to siting, grid and storage.
Close with the distinction: enough electricity depends on capacity and reserve margin, clean enough depends on carbon intensity, and both must be answered.

Add the counter check: wind and solar are intermittent, so any all renewable plan must also answer storage or backup, and a plan that does not is unfinished.
Students do: recompute the average with gas at 70 percent and coal at 5 percent, which is 325 grams per unit.
Students say: why nuclear is low carbon yet still carries other risks.

04 Question types and worked steps

Type Example Steps Answer
Solar output 5 kW with 3.2 sun hours Power times hours times 365 5,840 kWh
Wind output 3 MW at a 0.30 capacity factor Capacity times 0.30 times 8,760 7,884 MWh
Hydro power 100 metres head, 50 cubic metres per second, 85 percent rho g h Q eta About 41.7 MW
Carbon intensity Coal 25, gas 50, nuclear 25 percent Weight, then multiply by a thousand 425 grams per unit
Sanity check (teach this): Reasonable check: a capacity factor lies between 0 and 1, so 30 means a missing division by a hundred; a year holds 8,760 hours, so annual output above capacity times 8,760 is impossible; solar daily output cannot exceed capacity times 24 hours, so 16 kWh fits a 5 kW system while 120 does not; hydro needs cubic metres per second, and using litres per minute inflates the answer sixtyfold; a weighted carbon intensity must sit between the cleanest and dirtiest fuels, so 425 between 0 and 900 is plausible; gas rising while the average rises contradicts gas being cleaner than coal; a gap in percentage points is a subtraction, 7.5 minus 1 is 6.5, not a ratio; turbine counts must be whole numbers, and 0.33 means TWh and MWh differ by a thousand.

05 Independent practice (3 questions)

Question Answer What to watch
Solar 3 kW with 3.5 sun hours Check 3,832.5 kWh
Wind 5 MW at a 0.30 capacity factor Check 13,140 MWh
Carbon intensity Coal 5, gas 70, nuclear 25 percent Check 325 grams per unit

06 Common mistakes and what to say

Mistake Student writes Say this
Nuclear called renewable Nuclear emits no carbon, so it is renewable Renewable is a stock question about uranium, low carbon is an intensity question, and the two criteria stay separate.
Capacity factor read as hours A capacity factor of 0.30 means 0.3 hours a year It means thirty percent of the time at full output, so capacity times 0.30 times 8,760, giving 7,884 MWh for 3 MW.
Linear wind power Double the wind speed and output doubles Wind power rises with the cube of speed, so double speed is about eight times, until the cut out speed stops the turbine.
Only capacity answered Just install more panels Intermittency needs storage or backup, plus grid and land, so capacity alone answers half the question.

07 Homework (paper, section and question numbers)

08 Exit check (last 5 minutes)

Question Answer Decision
Two criteria Renewable is a stock question, clean is an intensity question Filing nuclear as renewable means the criteria were missed
Three formulas Solar power times hours, wind capacity times factor times 8,760, hydro rho g h Q eta Annual output above 8,760 hours means a unit error
Carbon intensity A weighted 425 grams per unit, 17 million tonnes a year Anything above the dirtiest fuel means the weighting was inverted

09 Tutor FAQ

Students have not met rho g h Q eta

Start with mgh becoming electricity, write the mass per second as rho Q, then multiply by efficiency, and the formula reads as a sentence.

How much local climate policy is needed

One line of background is enough: the target is a carbon intensity near zero, and students only need to know it is measurable.

How to keep this from becoming a debate

Keep every answer a number: grams per unit, payback years, turbine count, so claims can be checked and positions cannot replace arithmetic.