S3 Computer Literacy | Robotics and Automation Lesson Prep Guide | Sensing, Control Loops and Error Correction

S3 Computer Literacy | Robotics and Automation Lesson Prep Guide | Sensing, Control Loops and Error Correction

  • 2026-11-21

Students hear robot and picture an industrial arm, yet cannot say why the classroom buggy will not drive straight. This lesson reduces robotics to three parts: sensors read the state, a control loop compares target with actual, and error correction narrows the gap. Automation is that same loop repeated without a hand on the switch.

Objectives — Students can: (1) separate open-loop from closed-loop control and give one everyday example of each; (2) explain from sampling rate and control period why a robot reacts with delay; (3) compute travel distance from wheel diameter and encoder ticks, and explain why slip makes the real distance shorter.

01 Prerequisites (3-minute check)

If any of these fails, fix it before the lesson starts.

Skill Quick check Pass mark
Input and output Roles of sensor and actuator in a control system Sensor reads state, actuator changes it
Ratio and circumference How far a wheel of 6.5 cm diameter travels per turn About 20.4 cm
Unit conversion Milliseconds in one second 1000 ms

02 Lesson flow (60 minutes)

Time Stage Tutor does Student does
0-6 min Take a robot apart Split a buggy into sense, decide, act Draw three boxes with arrows
6-20 min Open and closed Contrast an old washing machine with an air conditioner One example each, say whether output is measured
20-34 min Period and delay Show a 20 ms loop against a 10 Hz sensor Work out loops per second and the gap between reads
34-46 min Distance maths Use 6.5 cm wheel and 20 ticks per turn Compute ticks for a 2 m run
46-55 min Correct the error Add 5 percent slip and compare Compute the real distance and name one fix
55-60 min Exit check Ask why adding a sensor can make the robot slower Answer with period and delay

03 Teaching script (read it out)

Scene 1: Split open loop from closed loop

Do not start with mechanics, start with one question: is the output measured. An old washing machine agitates for a set time without checking cleanliness, so it is open loop; an air conditioner reads room temperature before switching the compressor, so it is closed loop. Ask about the touch tap, the automatic door and the lift, and accept any answer that names the feedback.

Then state the cost: a sensor needs wiring, reading and a decision, so complexity rises. Robots are expensive because of that loop, not because of the shell.

Whether the output is measured is the dividing line

Scene 2: The period sets the reaction

A control program does not run continuously, it runs in rounds. A 20 ms period means 50 decisions per second, while a sensor at 10 Hz updates only every 100 ms. When the two rates differ, the slowest link sets the reaction.

Work one case: a buggy covering 30 cm per second with a sensor refreshing every 100 ms has already moved 3 cm between readings. When students compute that 3 cm themselves, the reason a fast robot hits things becomes obvious.

The slowest link sets the reaction

Scene 3: Measure the error before fixing it

A 6.5 cm wheel covers 20.4 cm per turn and the encoder gives 20 ticks per turn, so each tick is 1.02 cm. A 2 m run needs 9.8 turns, about 196 ticks, all of which students can do on a calculator.

Now add slip and the buggy travels only 190 cm, short by 10 cm. Offer three fixes: reduce acceleration, add a ground sensor to recalibrate, add a gyroscope to correct heading. Never say add a sensor without naming which error it corrects.

Target, then gap, then the exact fix

04 Question types and worked steps

Type Example Steps Answer
Classify control Automatic door and timed sprinkler Check whether output is measured Door is closed loop, sprinkler is open loop
Period to frequency A 20 ms control period Divide 1000 by the period 50 per second, that is 50 Hz
Distance conversion Wheel 6.5 cm, 20 ticks per turn, run 2 m Circumference first, then divide by ticks About 196 ticks
Error correction Slip of 5 percent Scale the target by the real ratio Only 190 cm travelled, so compensate or recalibrate
Sanity check (teach this): Sanity checks: decisions per second must equal 1000 divided by the period in milliseconds, so a negative or misplaced decimal means unconverted units; distance work multiplies by circumference before dividing by ticks, and reversing the order changes the answer by an order of magnitude; slip only shortens travel, so a longer answer is a sign error; an open-loop system cannot be described as self-correcting because it never measures its output; battery life must include efficiency, since ignoring it overstates the run time; a sensor slower than the loop just repeats the same reading.

05 Independent practice (3 questions)

Question Answer What to watch
Classify six devices Everyday machines around the room Check that feedback is the criterion
Convert three periods Three different period values Check the reciprocal and unit conversion
Compensate for slip Target distance plus slip ratio Check that the real value and a concrete fix both appear

06 Common mistakes and what to say

Mistake Student writes Say this
Calling an open loop closed Saying a timer switch corrects itself It never measures output, so an error goes unnoticed; feedback defines the closed loop
Swapping period and frequency Treating 20 ms as 20 decisions per second 1000 divided by 20 is 50; swapping makes the robot twice as fast on paper
Forgetting slip Counting ticks and assuming arrival Wheels spin, so real distance falls short; name the sensor or gyroscope fix
Ignoring efficiency Dividing battery capacity by motor power only Gears and motors lose about a fifth, so the raw figure overstates run time

07 Homework (paper, section and question numbers)

08 Exit check (last 5 minutes)

Question Answer Decision
Loops Feedback is the dividing line No feedback means redo the classification
Period 1000 divided by milliseconds Swapping means recompute three cases
Slip direction Travel comes out shorter A longer answer means redo the compensation

09 Tutor FAQ

How do robotics and automation differ

Robotics stresses programmable motion and sensing, automation stresses a process repeating without hands. Both share the same loop; one is about motion, the other about process.

Are encoders the only option

No. Ultrasonic, infrared and vision all work; encoders are cheap but suffer from slip, so precision systems combine two sources.

How long does a 12 V 2.5 Ah battery last

It stores 30 Wh against 10 W of motors, so 3.0 hours in theory and about 2.4 hours at eighty percent efficiency. Real loads shorten it further.